Date Message Added:
09/04/2012
Reviewed:
09/04/2012
201-865-002 Standalone Memory Test Aborted
Explanation:
No XSECSRAT key in OEM0 structure.
Internal Event:
No
Severity:
Warning
Serviceable:
No
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1. Perform the actions mentioned one at a time and try
the test after each action.
2. If the problem remains, contact your
technical-service representative.
3. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reseat DIMM(s). Reconnect it
to power.
4. Make sure that DSA and BIOS/uEFI are at the latest
level.
Date Message Added:
09/04/2012
Reviewed:
09/04/2012
201-865-003 Standalone Memory Test Aborted
Explanation:
No XSECSRAT key in OEM0 structure.
Internal Event:
No
Severity:
Warning
Serviceable:
No
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1. Perform the actions mentioned one at a time and try
the test after each action.
2. If the problem remains, contact your
technical-service representative.
3. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reseat DIMM(s). Reconnect it
to power.
4. Make sure that DSA and BIOS/uEFI are at the latest
level.
Date Message Added:
09/04/2012
Reviewed:
09/04/2012
201-866-000 Standalone Memory Test Aborted
Explanation:
EFI-SAL Invalid parameter from
GetMemoryMap function.
Internal Event:
No
Severity:
Warning
Serviceable:
No
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1. Perform the actions mentioned one at a time and try
the test after each action.
2. If the problem remains, contact your
technical-service representative.
3. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reseat DIMM(s). Reconnect it
to power.
4. Make sure that DSA and BIOS/uEFI are at the latest
level.
Date Message Added:
09/04/2012
Reviewed:
09/04/2012
201-866-001 Standalone Memory Test Aborted
Explanation:
EFI-SAL Invalid parameter from
GetMemoryMap function.
Internal Event:
No
Severity:
Warning
Serviceable:
No
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1. Perform the actions mentioned one at a time and try
the test after each action.
2. If the problem remains, contact your
technical-service representative.
3. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reseat DIMM(s). Reconnect it
to power.
4. Make sure that DSA and BIOS/uEFI are at the latest
level.
Date Message Added:
09/04/2012
Reviewed:
09/04/2012
201-866-002 Standalone Memory Test Aborted
Explanation:
EFI-SAL Invalid parameter from
GetMemoryMap function.
Internal Event:
No
201-865-002 • 201-866-002
228
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Содержание System x iDataPlex dx360 M4 7912
Страница 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 399: ......