W.305800D
[W.305800D] DRIVER HEALTH
PROTOCOL: Disconnect Controller
Failed. Requires 'Reboot'.
Explanation:
DRIVER HEALTH PROTOCOL:
Disconnect Controller Failed. Requires 'Reboot'
Severity:
Warning
User response:
Complete the following steps:
1.
Reboot the system to reconnect the controller.
2.
If problem persists, switch to backup UEFI or
reflash current UEFI image.
3.
(Trained Service Technician Only) Replace system
board.
W.305800E
[W.305800E] DRIVER HEALTH
PROTOCOL: Reports Invalid Health
Status Driver.
Explanation:
DRIVER HEALTH PROTOCOL: Reports
Invalid Health Status Driver
Severity:
Warning
User response:
Complete the following steps:
1.
Reboot the system.
2.
If problem persists, switch to backup UEFI or
reflash current UEFI image.
3.
(Trained Service Technician Only) Replace system
board.
W.3808000
[W.3808000] An IMM communication
failure has occurred.
Explanation:
IMM Communication Failure
Severity:
Warning
User response:
Complete the following steps:
1.
Reset IMM.
2.
Remove AUX power from the system. This will
reboot the entire system.
3.
Check IBM support site for an applicable service
bulletin or firmware update that applies to this error.
4.
Reflash UEFI Firmware.
5.
(Trained service technician only) Replace the
system board.
W.3808002
[W.3808002] An error occurred while
saving UEFI settings to the IMM.
Explanation:
Error Updating System Configuration to
IMM
Severity:
Warning
User response:
Complete the following steps:
1.
Use F1 Setup, Verify Settings and Save Settings to
recover settings.
2.
Reset IMM.
3.
Remove AUX power from the system. This will
reboot the entire system.
4.
Check IBM support site for an applicable service
bulletin or firmware update that applies to this error.
5.
Reflash IMM Firmware.
6.
Remove and re-install CMOS battery for 30
seconds to clear CMOS contents.
7.
(Trained Service technician only) Replace the
system board.
W.3808003
.[W.3808003] Unable to retrieve the
system configuration from the IMM.
Explanation:
Error Retrieving System Configuration
from IMM
Severity:
Warning
User response:
Complete the following steps:
1.
Use F1 Setup, Verify Settings and Save Settings to
recover settings.
2.
Reset IMM.
3.
Remove AUX power from the system. This will
reboot the entire system.
4.
Check IBM support site for an applicable service
bulletin or firmware update that applies to this error.
5.
Reflash IMM Firmware.
6.
Remove and re-install CMOS battery for 30
seconds to clear CMOS contents.
7.
(Trained Service technician only) Replace the
system board.
W.3818005
[W.3818005] The CRTM flash driver
could not successfully flash the
staging area. The update was aborted
Explanation:
CRTM Update Aborted
Severity:
Warning
User response:
Complete the following steps:
1.
Continue booting system. If system does not reset,
manually reset the system.
2.
If the error is not reported on the subsequent boot,
no additional recovery action is required.
3.
If the event persists, continue booting system and
reflash UEFI image.
4.
(Trained service technician only) Replace the
system board.
W.381800D
[W.381800D] TPM physical presence is
in asserted state
Explanation:
TPM physical presence is in asserted
state
Severity:
Warning
User response:
Complete the following steps:
W.305800D • W.381800D
28
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Содержание System x iDataPlex dx360 M4 7912
Страница 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 399: ......
Страница 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...