806f0a07-0302ffff
[ProcessorElementName] is
operating in a Degraded State. (CPU 2)
Explanation:
This message is for the use case when
an implementation has detected a Processor is running
in the Degraded state.
Internal Event:
No
Severity:
Warning
Alert Category:
Warning - CPU
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0038
SNMP Trap ID:
42
Automatically notify Support:
No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow (front and rear of
the server), that the air baffles are in place and
correctly installed, and that the server cover is
installed and completely closed.
2.
Check the ambient temperature. You must be
operating within the specifications.
3.
Make sure that the heat sink for microprocessor n
is installed correctly.
4.
(Trained technician only) Replace microprocessor
n. (n = microprocessor number)
806f0a0c-2001ffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 1)
Explanation:
This message is for the use case when
an implementation has detected an Over Temperature
Condition for Memory that has been Detected.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0146
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
1. Make sure that the fans are operating, that there are
no obstructions to the airflow, that the air baffles are
in place and correctly installed, and that the server
cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-2002ffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 2)
Explanation:
This message is for the use case when
an implementation has detected an Over Temperature
Condition for Memory that has been Detected.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0146
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
1. Make sure that the fans are operating, that there are
no obstructions to the airflow, that the air baffles are
in place and correctly installed, and that the server
cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-2003ffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 3)
Explanation:
This message is for the use case when
an implementation has detected an Over Temperature
Condition for Memory that has been Detected.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0146
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
1. Make sure that the fans are operating, that there are
no obstructions to the airflow, that the air baffles are
806f0a07-0302ffff • 806f0a0c-2003ffff
Chapter 3. Diagnostics
119
Содержание System x iDataPlex dx360 M4 7912
Страница 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 399: ......
Страница 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...