Alert Category:
Critical - Voltage
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0480
SNMP Trap ID:
1
Automatically notify Support:
Yes
User response:
If the specified sensor is CMOS
battery, replace the system battery. If the specified
sensor is Planar 3.3V or Planar 5V, (trained technician
only) replace the system board. If the specified sensor
is Planar 12V, complete the following steps until the
problem is solved:
1.
Check power supply n LED.
2.
Remove the failing power supply.
3.
Follow actions in "Power Problems and Solving
Power Problems".
4.
(Trained technician only) Replace the system
board. (n = power supply number)
80010204-1d01ffff
Numeric sensor
[NumericSensorElementName] going
low (lower critical) has asserted. (Fan 1
Tach)
Explanation:
This message is for the use case when
an implementation has detected a Lower Critical sensor
going low has asserted.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Fan Failure
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0480
SNMP Trap ID:
11
Automatically notify Support:
No
User response:
1.
Reseat the failing fan n, which is indicated by a lit
LED near the fan connector on the system board.
2.
Replace the failing fan. (n = fan number)
80010204-1d02ffff
Numeric sensor
[NumericSensorElementName] going
low (lower critical) has asserted. (Fan 2
Tach)
Explanation:
This message is for the use case when
an implementation has detected a Lower Critical sensor
going low has asserted.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Fan Failure
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0480
SNMP Trap ID:
11
Automatically notify Support:
No
User response:
1.
Reseat the failing fan n, which is indicated by a lit
LED near the fan connector on the system board.
2.
Replace the failing fan. (n = fan number)
80010204-1d03ffff
Numeric sensor
[NumericSensorElementName] going
low (lower critical) has asserted. (Fan 3
Tach)
Explanation:
This message is for the use case when
an implementation has detected a Lower Critical sensor
going low has asserted.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Fan Failure
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0480
SNMP Trap ID:
11
Automatically notify Support:
No
User response:
1.
Reseat the failing fan n, which is indicated by a lit
LED near the fan connector on the system board.
2.
Replace the failing fan. (n = fan number)
80010204-1d04ffff
Numeric sensor
[NumericSensorElementName] going
low (lower critical) has asserted. (Fan 4
Tach)
Explanation:
This message is for the use case when
an implementation has detected a Lower Critical sensor
going low has asserted.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Fan Failure
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0480
SNMP Trap ID:
11
Automatically notify Support:
No
User response:
1.
Reseat the failing fan n, which is indicated by a lit
LED near the fan connector on the system board.
2.
Replace the failing fan. (n = fan number)
80010204-1d01ffff • 80010204-1d04ffff
Chapter 3. Diagnostics
55
Содержание System x iDataPlex dx360 M4 7912
Страница 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 399: ......
Страница 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...