2.
Update the server firmware on the primary page.
Important: Some cluster solutions require specific
code levels or coordinated code updates. If the
device is part of a cluster solution, verify that the
latest level of code is supported for the cluster
solution before you update the code.
3.
(Trained technician only) Replace the system
board.
806f0113-0301ffff
A bus timeout has occurred on
system
[ComputerSystemElementName]. (CPU
1 PECI)
Explanation:
This message is for the use case when
an implementation has detected a Bus Timeout.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0224
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
1.
(Trained technician only)Reseat the microprocessor,
and then restart the server.
2.
(Trained technician only)Replace microprocessor n.
(n = microprocessor number)
806f0113-0302ffff
A bus timeout has occurred on
system
[ComputerSystemElementName]. (CPU
2 PECI)
Explanation:
This message is for the use case when
an implementation has detected a Bus Timeout.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0224
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
1.
(Trained technician only)Reseat the microprocessor,
and then restart the server.
2.
(Trained technician only)Replace microprocessor n.
(n = microprocessor number)
806f0123-2101ffff
Reboot of system
[ComputerSystemElementName]
initiated by [WatchdogElementName].
(IPMI Watchdog)
Explanation:
This message is for the use case when
an implementation has detected a Reboot by a
Watchdog occurred.
Internal Event:
No
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0370
SNMP Trap ID:
Automatically notify Support:
No
User response:
No action; information only.
806f0125-0b01ffff
[ManagedElementName]
detected as absent. (PCI Riser 1)
Explanation:
This message is for the use case when
an implementation has detected a Managed Element is
Absent.
Internal Event:
No
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0392
SNMP Trap ID:
Automatically notify Support:
No
User response:
Please ensure the PCI riser 1 has
been installed correctly.
806f0125-0b02ffff
[ManagedElementName]
detected as absent. (PCI Riser 2)
Explanation:
This message is for the use case when
an implementation has detected a Managed Element is
Absent.
Internal Event:
No
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0392
SNMP Trap ID:
Automatically notify Support:
No
User response:
Please ensure the PCI riser 1 has
been installed correctly.
806f0113-0301ffff • 806f0125-0b02ffff
Chapter 3. Diagnostics
87
Содержание System x iDataPlex dx360 M4 7912
Страница 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 399: ......
Страница 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...