SNMP Trap ID:
50
Automatically notify Support:
No
User response:
1.
Check the device driver.
2.
Reinstall the device driver.
3.
Update all device drivers to the latest level.
4.
Update the firmware (UEFI and IMM).
806f0322-1301ffff
Computer System
[ComputerSystemElementName] is in
Standby. (ACPI Power State)
Explanation:
This message is for the use case when
an implementation has detected a System went into
Standby mode.
Internal Event:
No
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0360
SNMP Trap ID:
Automatically notify Support:
No
User response:
No action; information only.
806f0323-2101ffff
Power cycle of system
[ComputerSystemElementName]
initiated by watchdog
[WatchdogElementName]. (IPMI
Watchdog)
Explanation:
This message is for the use case when
an implementation has detected a Power Cycle by
Watchdog occurred.
Internal Event:
No
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0374
SNMP Trap ID:
Automatically notify Support:
No
User response:
No action; information only.
806f040c-2001ffff
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (DIMM 1)
Explanation:
This message is for the use case when
an implementation has detected that Memory has been
Disabled.
Internal Event:
No
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0131
SNMP Trap ID:
Automatically notify Support:
No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
3.
Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in the
logs and no DIMM connector error LED is lit, you
can re-enable the DIMM through the Setup utility or
the Advanced Settings Utility (ASU).
806f040c-2002ffff
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (DIMM 2)
Explanation:
This message is for the use case when
an implementation has detected that Memory has been
Disabled.
Internal Event:
No
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0131
SNMP Trap ID:
Automatically notify Support:
No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
3.
Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in the
logs and no DIMM connector error LED is lit, you
can re-enable the DIMM through the Setup utility or
the Advanced Settings Utility (ASU).
806f0322-1301ffff • 806f040c-2002ffff
96
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Содержание System x iDataPlex dx360 M4 7912
Страница 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 399: ......
Страница 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...