Table 14. B200xxxx Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Reference Code
Description
Action
B2008151
System firmware detected an error.
Use the Integrated Virtualization Manager (IVM) or
management console to increase the Logical Memory
Block (LMB) size, and to reduce the number of virtual
devices for the partition.
B2008152
No active system processors.
Verify that processor resources are assigned to the
partition.
B2008160
A problem occurred during the
migration of a partition.
Contact IBM support.
B2008161
A problem occurred during the
migration of a partition.
Contact IBM support.
B200A100
A partition ended abnormally; the
partition could not stay running and
shut itself down.
1.
Check the error logs and take the actions for the error
codes that are found.
2.
Go to “Isolating firmware problems” on page 218.
B200A101
A partition ended abnormally; the
partition could not stay running and
shut itself down.
1.
Check the error logs and take the actions for the error
codes that are found.
2.
Go to “Isolating firmware problems” on page 218.
B200A140
A lower priority partition lost a
usable processor to supply it to a
higher priority partition with a bad
processor.
Evaluate the entire LPAR configuration. Adjust partition
profiles with the new number of processors available in
the system.
B200B07B
Informational system log entry only.
No corrective action is required.
B200B215
A problem occurred after a partition
ended abnormally.
There was a communications
problem between this partition's
service processor and the platform's
service processor.
Restart the platform.
B2005127
Timeout occurred during a main
store dump IPL.
There was not enough memory available for the dump to
complete before the timeout occurred. Retry the main
store dump IPL, or else power on the partition normally.
B2D03001
Informational system log entry only.
No corrective action is required.
B2D03002
Informational system log entry only.
No corrective action is required.
B200C1F0
An internal system firmware error
occurred during a partition
shutdown or a restart.
Go to “Isolating firmware problems” on page 218.
B200D150
A partition ended abnormally; there
was a communications problem
between this partition and the code
that handles resource allocation.
Check for server firmware updates; then, install the
updates if available.
B200E0AA
A problem occurred during the
power off of a partition.
Go to “Isolating firmware problems” on page 218.
38
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...