Table 25. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
2506-9042
-
Background Disk Array parity checking detected and corrected errors on specified
disk. Go to “Performing the checkout procedure” on page 184.
2506-9050
-
Required cache data can not be located for one or more disks. Go to “Performing the
checkout procedure” on page 184.
2506-9051
-
Cache data exists for one or more missing/failed disks. Go to “Performing the
checkout procedure” on page 184.
2506-9052
-
Cache data exists for one or more modified disks. Go to “Performing the checkout
procedure” on page 184.
2506-9054
-
RAID controller resources not available due to previous problems. Go to
“Performing the checkout procedure” on page 184.
2506-9060
-
One or more disk pairs are missing from a RAID-10 Disk Array. Go to “Performing
the checkout procedure” on page 184.
2506-9061
-
One or more disks are missing from a RAID-0 Disk Array. Go to “Performing the
checkout procedure” on page 184.
2506-9062
-
One or more disks are missing from a RAID-0 Disk Array. Go to “Performing the
checkout procedure” on page 184.
2506-9063
-
Maximum number of functional Disk Arrays has been exceeded. Go to “Performing
the checkout procedure” on page 184.
2506-9073
-
Multiple controllers connected in an invalid configuration. Go to “Performing the
checkout procedure” on page 184.
2506-9074
-
Multiple controllers not capable of similar functions or controlling same set of
devices. Go to “Performing the checkout procedure” on page 184.
2506-9075
-
Incomplete multipath connection between controller and remote controller. Go to
“Performing the checkout procedure” on page 184.
2506-9076
-
Missing remote controller. Go to “Performing the checkout procedure” on page 184.
2506-9081
-
Controller detected device error during internal media recovery. Go to “Performing
the checkout procedure” on page 184.
2506-9082
-
Controller detected device error during internal media recovery. Go to “Performing
the checkout procedure” on page 184.
2506-9090
-
Disk has been modified after last known status. Go to “Performing the checkout
procedure” on page 184.
2506-9091
-
Incorrect disk configuration change has been detected. Go to “Performing the
checkout procedure” on page 184.
2506-9092
-
Disk requires Format before use. Format the disk and retry the operation.
2506-FF3D
2506
Temporary controller failure. Retry the operation.
2506-FFF3
-
Disk media format bad. Reformat the disk and retry the operation.
2506-FFF4
722
Device problem. Perform diagnostics on the device and retry the operation.
2506-FFF6
722
Device detected recoverable error. Retry the operation.
2506-FFFA
722
Temporary device bus error. Retry the operation.
2506-FFFE
-
Temporary device bus error. Retry the operation.
252B-101
252B
Adapter configuration error.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
142
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...