v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Isolation
Procedure Code
Symptom
Action
FSPSP34
The memory cards
are plugged in an
invalid configuration
and cannot be used
by the system.
Install a DIMM for each of the dual processors on the BladeCenter PS700
blade server. Install the first pair in DIMM connectors 2 and 4.
Look for the following error codes in order. Follow the procedure for the
first code you find.
SRC B1xx C02A
A memory card is missing from the system.
The additional parts in the CRU callout list include all memory cards in
the group with the missing card. To correct the error, visually check the
system to determine which card is missing, and add the card.
SRC B1xx C029
A memory card is a different type than the other
memory cards in the same group.
The additional parts in the CRU callout list include all memory cards in
the group that contain the error. To correct the error, exchange the
memory cards of the incorrect type with those of the correct type.
SRC B1xx C02B
A group of memory cards are missing and are required
so that other memory cards on the board can be configured.
The additional parts in the CRU callout list include all the missing
memory cards in the group. To correct the error, add or move the
memory cards to the correct locations.
SRC B1xx C036
A memory card is not supported in this system.
The additional parts in the CRU callout list include all memory cards in
the group that contain the unsupported cards. To correct the error,
remove the unsupported cards from the system or replace them with the
correct type.
FSPSP35
The system has
detected a problem
with a memory
controller.
Enable redundant utilization by performing the following procedure:
1.
Power off the blade server, as described in “Turning off the blade
server” on page 7.
2.
Remove the blade server from the BladeCenter unit and reinsert the
blade server.
3.
Power on the blade server, as described in “Turning on the blade
server” on page 6.
FSPSP38
The system has
detected an error
within the JTAG
path.
Replace the CRU that is called out before this FSPSP38 call. If the CRU
that you replace does not correct the problem, call IBM Support.
FSPSP42
An error
communicating
between two system
processors was
detected.
Contact IBM Support.
208
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...