Table 25. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
652-731
2C8
A non-critical error has been detected: intermediate or system bus address parity
error. Schedule deferred maintenance. Go to “Performing the checkout procedure”
on page 184.
652-732
2C8
A non-critical error has been detected: intermediate or system bus data parity error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-733
2C8 292
A non-critical error has been detected: intermediate or system bus address parity
error. Schedule deferred maintenance. Go to “Performing the checkout procedure”
on page 184.
652-734
2C8 292
A non-critical error has been detected: intermediate or system bus data parity error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-735
2D2 292
A non-critical error has been detected: intermediate or system bus time-out error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-736
2D2 292
A non-critical error has been detected: intermediate or system bus time-out error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-770
2C8 292
A non-critical error has been detected: intermediate system bus address parity error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-771
2C8 292
A non-critical error has been detected: intermediate or system bus data parity error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-772
2D2 292
A non-critical error has been detected: intermediate or system bus time-out error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-773
227
A non-critical error has been detected: intermediate or system bus data parity error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-88x
The CEC or SPCN reported a non-critical error.
1.
Schedule deferred maintenance.
2.
Refer to the entry MAP in this system unit system service guide, with the 8-digit
error and location codes, for the necessary repair action.
3.
If the 8-digit error and location codes were NOT reported, then run diagnostics
in problem determination mode and record and report the 8-digit error and
location codes for this SRN.
652-89x
The CEC or SPCN reported a non-critical error.
1.
Schedule deferred maintenance.
2.
Refer to the entry MAP in this system unit system service guide, with the 8-digit
error and location codes, for the necessary repair action.
3.
If the 8-digit error and location codes were NOT reported, then run diagnostics
in problem determination mode and record and report the 8-digit error and
location codes for this SRN.
814-112
814
The NVRAM test failed. Go to “Performing the checkout procedure” on page 184.
814-113
221
The VPD test failed. Go to “Performing the checkout procedure” on page 184.
814-114
814
I/O Card NVRAM test failed. Go to “Performing the checkout procedure” on page
184.
Chapter 2. Diagnostics
137
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...