Table 14. B200xxxx Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Reference Code
Description
Action
B2005106
A problem occurred during the
startup of a partition. There is not
enough space to contain the partition
main storage dump. The startup will
not continue.
Verify that there is sufficient memory available to start the
partition as it is configured. If there is already enough
memory, then go to “Isolating firmware problems” on
page 218.
B2005109
A problem occurred during the
startup of a partition. There was a
partition main storage dump
problem. The startup will not
continue.
Go to “Isolating firmware problems” on page 218.
B2005114
A problem occurred during the
startup of a partition. There is not
enough space to contain the partition
main storage dump. The startup will
not continue.
Go to “Isolating firmware problems” on page 218.
B2005115
A problem occurred during the
startup of a partition. There was an
error reading the partition main
storage dump from the partition
load source into main storage. The
startup will attempt to continue.
If the startup does not continue, look for and resolve
other errors.
B2005117
A problem occurred during the
startup of a partition. A partition
main storage dump has occurred but
cannot be written to the load source
device because a valid dump already
exists.
Use the Main Storage Dump Manager to rename or copy
the current main storage dump.
B2005121
A problem occurred during the
startup of a partition. There was an
error writing the partition main
storage dump to the partition load
source. The startup will not
continue.
Look for related errors in the "Product Activity Log" and
fix any problems found. Use virtual control panel
function 34 to retry the current Main Store Dump startup
while the partition is still in the failed state.
B2005122
Informational system log entry only.
No corrective action is required.
B2005123
Informational system log entry only.
No corrective action is required.
B2005135
A problem occurred during the
startup of a partition. There was an
error writing the partition main
storage dump to the partition load
source. The main store dump startup
will continue.
Look for other errors and resolve them.
B2005137
A problem occurred during the
startup of a partition. There was an
error writing the partition main
storage dump to the partition load
source. The main store dump startup
will continue.
Look for other errors and resolve them.
34
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...