Table 15. B700xxxx Licensed internal code SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
Description
Action
6907
System bus error
1.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
2.
Go to “Isolating firmware problems” on
page 218.
6908
System bus error
Replace the system-board and chassis
assembly, as described in “Replacing the FRU
system-board and chassis assembly” on page
260.
6909
System bus error
1.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
2.
Go to “Isolating firmware problems” on
page 218.
6911
Platform LIC unable to find or retrieve
VPD LID file.
Check for server firmware updates; then,
install the updates if available.
6912
Platform LIC unable to find or retrieve
VPD LID file.
Check for server firmware updates; then,
install the updates if available.
6944
Informational system log entry only.
No corrective action is required.
6950
A platform dump has occurred.
1.
Collect the platform dump information.
2.
Go to “Isolating firmware problems” on
page 218.
6951
An error occurred because a partition
needed more NVRAM than was
available.
Use the Integrated Virtualization Manager
(IVM) or management console to delete one or
more partitions.
6952
Informational system log entry only.
No corrective action is required.
6953
PHYP NVRAM is unavailable after a
service processor reset and reload.
Go to “Isolating firmware problems” on page
218.
6954
Informational system log entry only.
No corrective action is required.
6955
Informational system log entry only.
No corrective action is required.
6956
An NVRAM failure was detected.
Go to “Isolating firmware problems” on page
218.
6965
Informational system log entry only.
No corrective action is required.
6970
PCI host bridge failure
1.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
2.
If the problem persists, use the “PCI
expansion card (PIOCARD) problem
isolation procedure” on page 194 to
determine the failing component.
Chapter 2. Diagnostics
45
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......