Table 7. 1xxxyyyy SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
1xxxyyyy
Error
Codes
Description
Action
267A
HSDC/4xel_A0_pGood fault
Perform the DTRCARD symbolic CRU isolation procedure by
completing the following steps:
1.
Reseat the PCIe expansion card.
2.
If the problem persists, replace the expansion card.
3.
If the problem persists, go to the “Checkout procedure” on page
184.
4.
If the problem persists, replace the system-board and chassis
assembly, as described in “Replacing the FRU system-board and
chassis assembly” on page 260.
The DTRCARD symbolic CRU isolation procedure is in “Service
processor problems” on page 200
267B
HSDC/4xel_B0_pGood fault
Perform the DTRCARD symbolic CRU isolation procedure by
completing the following steps:
1.
Reseat the PCIe expansion card.
2.
If the problem persists, replace the expansion card.
3.
If the problem persists, go to the “Checkout procedure” on page
184.
4.
If the problem persists, replace the system-board and chassis
assembly, as described in “Replacing the FRU system-board and
chassis assembly” on page 260.
The DTRCARD symbolic CRU isolation procedure is in “Service
processor problems” on page 200
267C
REG_P5IO2C_core 1.2V pGood
fault
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in “Replacing the FRU
system-board and chassis assembly” on page 260.
267D
2.0_PLL_pGood fault
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in “Replacing the FRU
system-board and chassis assembly” on page 260.
2710
pGood output/
P7_VRM_PVID_gate fault
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in “Replacing the FRU
system-board and chassis assembly” on page 260.
3120
VRM voltage adjustment failure
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in “Replacing the FRU
system-board and chassis assembly” on page 260.
20
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...