Table 14. B200xxxx Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Reference Code
Description
Action
B2001142
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the
updates if available.
B2001143
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the
updates if available.
B2001144
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the
updates if available.
B2001148
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the
updates if available.
B2001150
During the startup of a partition, a
partitioning configuration problem
occurred.
Go to “Verifying the partition configuration” on page 186.
B2001151
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the
updates if available.
B2001170
During the startup of a partition, a
failure occurred due to a validation
error.
Go to “Verifying the partition configuration” on page 186.
B2001225
A problem occurred during the
startup of a partition.
The partition attempted to start up
prior to the platform fully
initializing. Restart the partition after
the platform has fully completed and
the platform is not in standby mode.
Restart the partition.
B2001230
During the startup of a partition, a
partitioning configuration problem
occurred; the partition is lacking the
necessary resources to start up.
Go to “Verifying the partition configuration” on page 186.
B2001260
A problem occurred during the
startup of a partition.
The partition could not start at the
Timed Power On setting because the
partition was not set to Normal.
Set the partition to Normal.
30
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...