Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Isolation
Procedure Code
Symptom
Action
ANYPROC
Symbolic CRU
The failing
component is one of
the system
processors.
Replace the system board and chassis assembly, as described in
“Replacing the FRU system-board and chassis assembly” on page 260.
BCPROB
Symbolic CRU
Error code 1xxx2670
indicates that the
BladeCenter
encountered a
problem, and the
blade server was
automatically shut
down as a result.
1.
Check the management-module event log for entries that were made
around the time that the PS700 blade server shut down.
2.
Resolve any problems.
3.
Remove the blade from the BladeCenter unit and then reinsert the
blade server.
4.
Power on the blade server.
5.
Monitor the blade server operation to verify that the problem is
solved.
6.
If the BladeCenter unit is functioning normally, but the 1xxx2670
problem persists, replace the system board and chassis assembly, as
described in “Replacing the FRU system-board and chassis assembly”
on page 260.
CAPACTY
Symbolic CRU
The failing
component is the
management card.
1.
Replace the management card, as described in “Removing the tier 2
management card” on page 255 and “Installing the tier 2
management card” on page 256.
2.
After replacing the card and installing the blade server in the chassis
unit and before rebooting the blade server or performing other
operations, ensure that the initialization of the management card
VPD occurs by waiting for the management module to discover the
blade server. Otherwise, the system might fail to IPL.
CLCKMOD
Symbolic CRU
The logic oscillator is
failing.
Replace the system board and chassis assembly, as described in
“Replacing the FRU system-board and chassis assembly” on page 260.
DTRCARD
Symbolic CRU
Error code 1xxx2625,
2626, or 2527
indicates that the
blade server is
reporting a problem
with the PCIe
expansion card.
1.
Reseat the PCIe expansion card.
2.
If the problem persists, replace the expansion card.
3.
If the problem persists, go to “Checkout procedure” on page 184.
4.
If the problem persists, replace the system board and chassis
assembly, as described in “Replacing the FRU system-board and
chassis assembly” on page 260.
Chapter 2. Diagnostics
201
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...