Table 14. B200xxxx Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Reference Code
Description
Action
B2002058
A problem occurred during a
partition Main Storage Dump. A
mainstore dump startup did not
complete due to a copy error.
Go to “Isolating firmware problems” on page 218.
B2002210
Informational system log entry only.
No corrective action is required.
B2002220
Informational system log entry only.
No corrective action is required.
B2002250
During the startup of a partition, an
attempt to toggle the power state of
a slot has failed.
Check for server firmware updates; then, install the
updates if available.
B2002260
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 218.
B2002300
During the startup of a partition, an
attempt to toggle the power state of
a slot has failed.
Check for server firmware updates; then, install the
updates if available.
B2002310
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 218.
B2002320
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 218.
B2002425
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 218.
B2002426
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 218.
B2002475
During the startup of a partition, a
slot that was needed for the partition
was either empty or the device in
the slot has failed.
Check for server firmware updates; then, install the
updates if available.
B2002485
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 218.
B2003000
Informational system log entry only.
No corrective action is required.
B2003081
During the startup of a partition, the
startup did not complete due to a
copy error.
Check for server firmware updates; then, install the
updates if available.
B2003084
A problem occurred during the
startup of a partition.
The adapter type might not be
supported.
Verify that the adapter type is supported.
B2003088
Informational system log entry only.
No corrective action is required.
32
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...