Table 25. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
651-841
152 2E2
Sensor detected a voltage outside of the normal range. Go to “Performing the
checkout procedure” on page 184.
651-842
2E1
Sensor detected an abnormally high internal temperature. Make sure that:
1.
The room ambient temperature is within the system operating environment.
2.
There is unrestricted air flow around the system.
3.
All system covers are closed.
4.
There are no fan failures.
651-90x
Platform-specific error. Call your support center.
652-600
A non-critical error has been detected: uncorrectable memory or unsupported
memory. Schedule deferred maintenance. Examine the memory modules and
determine if they are supported types. If the modules are supported, then replace
the appropriate memory modules.
652-610
210
A non-critical error has been detected: CPU internal error. Schedule deferred
maintenance. Go to “Performing the checkout procedure” on page 184.
652-611
210
A non-critical error has been detected: CPU internal cache or cache controller error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-612
D01
A non-critical error has been detected: external cache parity or multi-bit ECC error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-613
D01
A non-critical error has been detected: external cache ECC single-bit error. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
652-623
2C6
A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
652-630
307
A non-critical error has been detected: I/O expansion bus parity error. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
652-631
307
A non-critical error has been detected: I/O expansion bus time-out error. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
652-632
307
A non-critical error has been detected: I/O expansion bus connection failure.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-633
307
A non-critical error has been detected: I/O expansion unit not in an operating state.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-634
307
A non-critical error has been detected: internal device error. Schedule deferred
maintenance. Go to “Performing the checkout procedure” on page 184.
652-664
302
A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
652-665
303
A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
652-666
304
A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
652-669
2CD
A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred G maintenance. Go to “Performing the checkout procedure” on page 184.
652-66A
2CE
A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
652-66B
2CC
A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
136
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......