Table 25. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
950-2506
2506 221
Missing options resolution for 3Gb SAS Adapter card.
Try each of the following steps. After reseating, removing, or replacing a part, retry
the operation.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Reseat the 3Gb SAS Adapter card.
4.
Replace the 3Gb SAS Adapter card.
5.
Replace the system-board.
2506-102E
722
Out of alternate disk storage for storage. Go to “Performing the checkout procedure”
on page 184.
2506-3002
722
Addressed device failed to respond to selection. Go to “Performing the checkout
procedure” on page 184.
2506-3010
722
Disk returned wrong response to adapter. Go to “Performing the checkout
procedure” on page 184.
2506-3020
-
Storage subsystem configuration error. Go to “Performing the checkout procedure”
on page 184.
2506-3100
-
Controller detected device bus interface error. Go to “Performing the checkout
procedure” on page 184.
2506-3109
-
Controller timed out a device command. Go to “Performing the checkout procedure”
on page 184.
2506-3110
-
Device bus interface error. Go to “Performing the checkout procedure” on page 184.
2506-4010
-
Configuration error, incorrect connection between cascaded enclosures. Go to
“Performing the checkout procedure” on page 184.
2506-4020
-
Configuration error, connections exceed IOA design limits. Go to “Performing the
checkout procedure” on page 184.
2506-4030
-
Configuration error, incorrect multipath connection. Go to “Performing the checkout
procedure” on page 184.
2506-4040
-
Configuration error, incomplete multipath connection between controller and
enclosure detected. Go to “Performing the checkout procedure” on page 184.
2506-4041
-
Configuration error, incomplete multipath connection between enclosure and device
detected. Go to “Performing the checkout procedure” on page 184.
2506-4050
-
Attached enclosure does not support required multipath function. Go to “Performing
the checkout procedure” on page 184.
2506-4060
-
Multipath redundancy level got worse. Go to “Performing the checkout procedure”
on page 184.
2506-4100
-
Device bus fabric error. Go to “Performing the checkout procedure” on page 184.
2506-4101
-
Temporary device bus fabric error. Go to “Performing the checkout procedure” on
page 184.
2506-4110
-
Unsupported enclosure function detected. Go to “Performing the checkout
procedure” on page 184.
2506-4150
2506
PCI bus error detected by controller. Go to “Performing the checkout procedure” on
page 184.
2506-4160
2506
PCI bus error detected by controller. Go to “Performing the checkout procedure” on
page 184.
2506-7001
722
Temporary disk data error. Go to “Performing the checkout procedure” on page 184.
140
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...