Table 14. B200xxxx Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Reference Code
Description
Action
B2005145
A problem occurred during the
startup of a partition. There was an
error writing the partition main
storage dump to the partition load
source. The main store dump startup
will continue.
Look for other errors and resolve them.
B2005148
A problem occurred during the
startup of a partition. An error
occurred while doing a main storage
dump that would have caused
another main storage dump. The
startup will not continue.
Go to “Isolating firmware problems” on page 218.
B2005149
A problem occurred during the
startup of a partition while doing a
Firmware Assisted Dump that would
have caused another Firmware
Assisted Dump.
Check for server firmware updates; then, install the
updates if available.
B200514A
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the
updates if available.
B200542A
A Firmware Assisted Dump did not
complete due to a read error.
Check for server firmware updates; then, install the
updates if available.
B200542B
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the
updates if available.
B200543A
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the
updates if available.
B200543B
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the
updates if available.
B200543C
Informational system log entry only.
No corrective action is required.
B200543D
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the
updates if available.
B2006006
During the startup of a partition, a
system firmware error occurred
when the partition memory was
being initialized; the startup will not
continue.
Go to “Isolating firmware problems” on page 218.
B2006006
A problem occurred during the
startup of a partition. The partition
could not reserve the memory
required for IPL.
Contact IBM support.
B2006012
During the startup of a partition, the
partition LID failed to completely
load into the partition main storage
area.
Go to “Isolating firmware problems” on page 218.
Chapter 2. Diagnostics
35
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...