Table 27. A00-FF0 through A24-xxx SRNs (continued)
SRN
Description
FRU/action
A1D-19x
A non-critical error has been detected, a
service processor error accessing real
time clock/time-of-day clock.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-20x
A non-critical error has been detected:
Service processor error accessing scan
controller/hardware.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-21x
A non-critical error has been detected, a
service processor detected error with
time-of-day clock backup battery.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-23x
A non-critical error has been detected:
Loss of heart beat from Service
Processor.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-24x
A non-critical error has been detected, a
service processor detected a
surveillance time-out.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-29x
A non-critical error has been detected, a
service process error accessing power
control network.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-30x
A non-critical error has been detected:
Non-supported hardware.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-31x
A non-critical error has been detected:
Error detected while handling an
attention/interrupt from the system
hardware.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
Chapter 2. Diagnostics
175
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...