Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
Error code
Description
Action
BA154070
The receive operation failed.
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA170000
NVRAMRC initialization failed; device
test failed
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA170100
NVRAM data validation check failed
1.
Shut down the blade server; then, restart it.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA170201
The firmware was unable to expand
target partition - saving configuration
variable
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA170202
The firmware was unable to expand
target partition - writing event log entry
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA170203
The firmware was unable to expand
target partition - writing VPD data
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA170210
Setenv/$Setenv parameter error - name
contains a null character
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
72
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...