Table 22. D1001xxx to D1xx3FFF dump codes (continued)
v
If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in
the Action column until the problem is solved. If an action solves the problem, you can stop performing the
remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
Progress code
Description
Action
D1291xxx
Dump output the calculated CRC2 (data
and data headers)
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
D12A1xxx
Jump to the position in dump directly
after CRC1
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
D12B1xxx
Initialize the headers dump time and
serial numbers
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
D12C1xxx
Display final SRC to panel
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
D12D1xxx
Rmove /core/core.app.time.pid
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
D12E1xxx
Remove /core/core.*
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
D12F1xxx
Display beginning SRC to panel
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
D1301xxx
Turn off error log capture into dump
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
D1311xxx
Turn on error log capture into dump
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
D1321xxx
Store information about existing core
files
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
124
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...