Table 25. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
2624-xxx
2624
Generic reference for 4X PCI-E DDR InfiniBand Host Channel Adapter -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 184.
2624-101
2624
Configuration failure - system-board and chassis assembly. Go to “Performing the
checkout procedure” on page 184.
2624-102
2624
Queue pair create failure - system-board and chassis assembly. Go to “Performing
the checkout procedure” on page 184.
2624-103
2624
Loop back test failure - system-board and chassis assembly. Go to “Performing the
checkout procedure” on page 184.
2624-201
cable
network
Loop back test failure. Do the following steps one at a time, in order, and rerun the
test after each step:
1.
Reseat the cable.
2.
Replace the cable.
3.
Verify that the network is functional.
4.
Verify that the network switch is functional.
2624-301
cable
network
2624
Loop back test failure. Do the following steps one at a time, in order, and rerun the
test after each step:
1.
Reseat the cable.
2.
Replace the cable.
3.
Verify that the network is functional.
4.
Verify that the network switch is functional.
5.
Go to “Performing the checkout procedure” on page 184.
2624-701
2624
Error Log Analysis indicates that this adapter has failed due to an internal error -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 184.
2624-702
2624
Error Log Analysis indicates that this adapter has failed due to a failure with the
uplink interface used to connect this device to the host processor - system-board and
chassis assembly. Go to “Performing the checkout procedure” on page 184.
2624-703
2624
Error Log Analysis indicates that this adapter has failed due to a memory error -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 184.
2624-704
2624
Error Log Analysis indicates that this adapter has failed due to a unrecoverable
internal parity error - system-board and chassis assembly. Go to “Performing the
checkout procedure” on page 184.
2624-705
2624
Error Log Analysis indicates that this adapter has failed due to a internal error -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 184.
2624-706
2624
Error Log Analysis indicates that this adapter has failed due to a memory error -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 184.
2640-121
2640
Physical volume hardware error. Go to “Performing the checkout procedure” on
page 184.
2640-131
2640
Smart status threshold exceeded. Go to “Performing the checkout procedure” on
page 184.
2640-132
2640
Command timeouts threshold exceeded. Go to “Performing the checkout procedure”
on page 184.
2640-133
2640
Command timeout with error condition. Go to “Performing the checkout procedure”
on page 184.
148
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...