Table 25. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
2640-134
2640
Hardware command or DMA failure. Go to “Performing the checkout procedure” on
page 184.
2640-136
2640 2631
Timeout waiting for controller or drive with no busy status. Go to “Performing the
checkout procedure” on page 184.
2D02-xxx
2631
Generic reference for USB controller/adapter - system-board and chassis assembly.
Go to “Performing the checkout procedure” on page 184.
2E00-201
2E00 221
Configuration error.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
2E00-601
2E00
EEPROM read error
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
2E00-701
2E00 221
Permanent adapter failure.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
2E10-201
2E10 221
Adapter configuration error.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
2E10-601
2E10
Error Log Analysis indicates adapter failure.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
2E10-602
2E10
Error Log Analysis indicates an Error Attention condition.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
2E10-603
2E10
Error Log Analysis indicates that the microcode could not be loaded on the adapter.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
2E10-604
2E10
Error Log Analysis indicates a permanent adapter failure.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
Chapter 2. Diagnostics
149
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...