Table 27. A00-FF0 through A24-xxx SRNs (continued)
SRN
Description
FRU/action
A0D-36x
Other IPL Diagnostic Error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A0D-37x
Clock or PLL Error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A0D-38x
Hardware Scan or Initialization Error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A0D-40x
FRU Presence/Detect Error
(Mis-Plugged).
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A10-100
The resource is unavailable due to an
error. System is operating in degraded
mode.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A10-200
The resource was marked failed by the
platform. The system is operating in
degraded mode.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A10-210
The processor has been deconfigured.
The system is operating in degraded
mode.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A11-00x
A non-critical error has been detected.
Error log analysis indicates an error
detected by the microprocessor, but the
failure could not be isolated.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
Chapter 2. Diagnostics
165
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...