Table 27. A00-FF0 through A24-xxx SRNs (continued)
SRN
Description
FRU/action
A11-01x
A non-critical error has been detected, a
CPU internal error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A11-02x
A non-critical error has been detected, a
CPU internal cache or cache controller
error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A11-03x
A non-critical error has been detected,
an external cache parity or multi-bit
ECC error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, see “Solving
undetermined problems” on page 227
A11-05x
A non-critical error has been detected, a
system bus time-out error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A11-06x
A non-critical error has been detected, a
time-out error waiting for an I/O
device.
Check the BladeCenter management-module
event log for an entry around this time. If no
entry is found, replace the system-board and
chassis assembly.
A11-50x
Recoverable errors on resource indicate
a trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use. The
system is operating with the potential
for an unrecoverable error.
1.
If repair is not immediately available, reboot
and the resource will be deconfigured;
operations can continue in a degraded mode.
2.
Check the BladeCenter management-module
event log for an entry around this time. If no
entry is found, replace the system-board and
chassis assembly.
A11-510
Resource has been deconfigured and is
no longer in use due to a trend toward
an unrecoverable error.
1.
Schedule maintenance; the system is
operating in a degraded mode.
2.
Check the BladeCenter management-module
event log for an entry around this time. If no
entry is found, replace the system-board and
chassis assembly.
A11-540
Recoverable errors on resource indicate
a trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use. The
system is operating with the potential
for an unrecoverable error.
1.
If repair is not immediately available, reboot
and the resource will be deconfigured;
operations can continue in a degraded mode.
2.
Check the BladeCenter management-module
event log for an entry around this time. If no
entry is found, replace the system-board and
chassis assembly.
166
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...