7.
Replace the monitor cable, if applicable.
8.
Replace the monitor.
9.
Replace the management module.
See the online information center or the
Problem Determination and Service Guide
or the
Hardware
Maintenance Manual and Troubleshooting Guide
for your BladeCenter unit.
Solving undetermined problems
When you are diagnosing a problem in the PS700 blade server, you must determine whether the problem
is in the blade server or in the BladeCenter unit.
v
If all of the blade servers have the same symptom, it is probably a BladeCenter unit problem; for more
information, See the online information or the
Hardware Maintenance Manual and Troubleshooting Guide
or
Problem Determination and Service Guide
for your BladeCenter unit.
v
If the BladeCenter unit contains more than one blade server and only one of the blade servers has the
problem, troubleshoot the blade server that has the problem.
Check the LEDs on all the power supplies of the BladeCenter unit where the blade server is installed. If
the LEDs indicate that the power supplies are working correctly, and reseating the blade server does not
correct the problem, complete the following steps:
1.
Make sure that the control panel connector is correctly seated on the system board. See “System-board
connectors” on page 8 for the location of the connector.
2.
If no LEDs on the control panel are working, replace the bezel assembly; then, try to power-on the
blade server from the BladeCenter Web interface. See the online information or the
BladeCenter
Management Module User's Guide
for more information.
3.
Turn off the blade server.
4.
Remove the blade server from the BladeCenter unit and remove the cover.
5.
Remove or disconnect the following devices, one at a time, until you find the failure. Reinstall, turn
on, and reconfigure the blade server each time.
v
I/O expansion option.
v
Hard disk drives.
v
Memory modules. The minimum configuration requirement is 2 GB (two 1 GB DIMMs).
The following minimum configuration is required for the blade server to start:
v
System-board and chassis assembly (with two microprocessors)
v
Two 2 GB DIMMs
v
A functioning BladeCenter unit
6.
Install and turn on the blade server. If the problem remains, suspect the following components in
order:
a.
DIMM
b.
System-board and chassis assembly
Chapter 2. Diagnostics
227
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...