Table 27. A00-FF0 through A24-xxx SRNs (continued)
SRN
Description
FRU/action
A1D-34x
A non-critical error has been detected:
Wire Test Error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-35x
A non-critical error has been detected:
Mainstore or Cache IPL Diagnostic
Error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-37x
A non-critical error has been detected:
Clock or PLL Error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-38x
A non-critical error has been detected:
Hardware Scan or Initialization Error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-40x
A non-critical error has been detected:
Presence/Detect Error (Mis-Plugged).
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-50x
Recoverable errors on resource indicate
a trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use. The
system is operating with the potential
for an unrecoverable error.
1.
If repair is not immediately available, reboot
and the resource will be deconfigured;
operations can continue in a degraded mode.
2.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
3.
If no entry is found, Replace the
system-board.
A24-000
Spurious interrupts on shared interrupt
level have exceeded threshold
1.
Check the BladeCenter management-module
event log. If an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
Replace part numbers reported by the
diagnostic program.
3.
If no entry is found, Replace the
system-board.
176
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...