Table 25. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
651-140
221
Display Character test failed.
Note:
Diagnostic will provide this SRN but there is no action to be taken. Do not
perform operator panel test from diagnostics.
651-151
152 2E2
Sensor indicates a voltage is outside the normal range. Go to “Performing the
checkout procedure” on page 184.
651-152
2E1
Sensor indicates an abnormally high internal temperature. Verify that:
1.
The room ambient temperature is within the system operating environment.
2.
There is unrestricted air flow around the system.
3.
All system covers are closed.
4.
Verify that all fans in the BladeCenter unit are operating correctly.
651-159
210
Sensor indicates a FRU has failed. Use the failing function codes, use the physical
location code(s) from the diagnostic problem report screen to determine the FRUs.
651-161
2E2
Sensor indicates a voltage is outside the normal range. Go to “Performing the
checkout procedure” on page 184.
651-162
2E1
Sensor indicates an abnormally high internal temperature. Verify that:
1.
The room ambient temperature is within the system operating environment.
2.
There is unrestricted air flow around the system.
3.
There are no fan or blower failures in the BladeCenter unit.
If the problem remains, check the management-module event log for possible causes
of overheating.
651-169
Sensor indicates a FRU has failed. Go to “Performing the checkout procedure” on
page 184.
651-170
Sensor status not available. Go to “Performing the checkout procedure” on page 184.
651-171
Sensor status not available. Go to “Performing the checkout procedure” on page 184.
651-600
Uncorrectable memory or unsupported memory.
1.
Examine the memory modules and determine if they are supported types.
2.
If the modules are supported, then reseat the DIMMs.
3.
Replace the appropriate memory modules.
651-601
Missing or bad memory. If the installed memory matches the reported memory size,
then replace the memory; otherwise, add the missing memory.
651-602
2C7
Failed memory module. Go to “Performing the checkout procedure” on page 184.
651-603
2C6 2C7
Failed memory module. Go to “Performing the checkout procedure” on page 184.
651-605
2C6
Memory module has no matched pair. The most probable failure is the memory
module paired with the memory module identified by the location code.
1.
Examine the memory modules and determine if they are supported types.
2.
If the modules are supported, then reseat the DIMMs.
3.
Replace the appropriate memory modules.
651-608
D01
Bad L2 cache. Go to “Performing the checkout procedure” on page 184.
651-609
D01
Missing L2 cache. Go to “Performing the checkout procedure” on page 184.
651-610
210
CPU internal error. Go to “Performing the checkout procedure” on page 184.
651-611
210
CPU internal cache controller error. Go to “Performing the checkout procedure” on
page 184.
651-612
D01
External cache ECC single-bit error. Go to “Performing the checkout procedure” on
page 184.
Chapter 2. Diagnostics
131
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...