6 - 57
TEST PROCEDURE
Test 14 : Check voltage between connector
CN-88 - GND.
Start key ON.
Disconnect connector CN-88 from power
max solenoid valve.
Check voltage as figure.
(1)
ڸ
ڹ
ں
2)
Test 15 : Check resistance between
connector CN-50(21)-GND.
Starting key OFF.
Remove CPU controller and disconnect
connector CN-50 from CPU controller.
Check resistance as figure.
(2)
ڸ
ڹ
ں
Power max.
solenoid valve
CN-88
Multimeter
CN-88
LH lever
Power max. switch
CN-50
CPU
CONTROLLER
CN-51
CN-52
CN-53
Ground
15
12
11
10
9
1
2
3
17 18 19
Multimeter
CN-50
20 21 22
4
5
6
13 14
7
8
16
23 24
SPEC : Key ON : 24
Ź
1V
Key OFF : 0V
Resistance : 15~30
װ
SPEC : Power max button pressed ON : 0
װ
Power max button released OFF :
ſװ
Содержание R 160 LC-3
Страница 9: ......
Страница 142: ...4 4...
Страница 152: ...4 14 BEACONLAMPCIRCUIT FUSE BOX BEACON LAMP SW BEACON LAMP 2 3 1 4 4 CN 2 CN 14 CL 7 CN 6 CN 1 CN 36 CS 23...
Страница 171: ...4 33 No of pin Receptacle connector Female Plug connector Male 20 1 11 10 20 S817 020105 MULTILOCK TYPE CONNECTOR 2...
Страница 182: ...4 44 No of pin Receptacle connector Female Plug connector Male 24 12 24 1 13 S815 024000...
Страница 394: ...8 81 8 Fit spool 34 spring 35 to base plate 3 and tighten plug 36 Pay attention to spool direction...
Страница 397: ......
Страница 398: ......
Страница 399: ......
Страница 400: ......
Страница 401: ......
Страница 402: ......
Страница 403: ......
Страница 404: ......
Страница 405: ......
Страница 406: ......
Страница 407: ......
Страница 416: ...8 103 Remove lock nut 21 and then boot 26 15...
Страница 427: ...8 114 Install cover 3 to hub 1 and tighten bolts 14 Torque 5 5 12 5kgf m 40 90lbf ft 7 14 15 3...
Страница 456: ...8 143 1 STRUCTURE GROUP 11 WORKEQUIPMENT SECTION A SECTION B SECTION C C B B A A C...