6 - 20
YES
NO
Is genuine
hydraulic oil or
equivalent being
used?
Is not hydraulic oil
temperature high?
Does the symptom
change when port
relief valve is
replaced with
normal valve?
BOOM, ARM OR BUCKET CYLINDER EXTENDS OR CONTRACTS ITSELF AND ATTACHMENT FALLS
3)
Normal
YES
YES
NO
NO
OK
NO
Port relief valve is
faulty.
ڞ
Control valve's
return spring is
faulty.
Pressure tightness
between control
valve casing and
spool is poor.
Contact surface
between poppet
and seat is poor.
Cylinder is faulty.
Disassemble and
repair or replace.
Disassemble and
replace.
Locate the cause
of hydraulic oil
temperature rise
and lower it to
proper level.
Replace with
genuine hydraulic
oil or equivalent.
Disassemble and
repair.
Disassemble and
repair.
Disassemble and
repair.
ڞ
Is cylinder internal
leakage within
standard level?
Abnormal
Abnormally high.
Is control valve
return spring
normal?
Disassemble and
inspect check
valve in hydraulic
circuit and check
for any fault.
YES
Cause
Remedy
Содержание R 160 LC-3
Страница 9: ......
Страница 142: ...4 4...
Страница 152: ...4 14 BEACONLAMPCIRCUIT FUSE BOX BEACON LAMP SW BEACON LAMP 2 3 1 4 4 CN 2 CN 14 CL 7 CN 6 CN 1 CN 36 CS 23...
Страница 171: ...4 33 No of pin Receptacle connector Female Plug connector Male 20 1 11 10 20 S817 020105 MULTILOCK TYPE CONNECTOR 2...
Страница 182: ...4 44 No of pin Receptacle connector Female Plug connector Male 24 12 24 1 13 S815 024000...
Страница 394: ...8 81 8 Fit spool 34 spring 35 to base plate 3 and tighten plug 36 Pay attention to spool direction...
Страница 397: ......
Страница 398: ......
Страница 399: ......
Страница 400: ......
Страница 401: ......
Страница 402: ......
Страница 403: ......
Страница 404: ......
Страница 405: ......
Страница 406: ......
Страница 407: ......
Страница 416: ...8 103 Remove lock nut 21 and then boot 26 15...
Страница 427: ...8 114 Install cover 3 to hub 1 and tighten bolts 14 Torque 5 5 12 5kgf m 40 90lbf ft 7 14 15 3...
Страница 456: ...8 143 1 STRUCTURE GROUP 11 WORKEQUIPMENT SECTION A SECTION B SECTION C C B B A A C...