6 - 24
GROUP 3 ELECTRICAL SYSTEM
1. WHEN STARTING SWITCH IS TURNED ON, MONITOR PANEL DISPLAY DOES NOT APPEAR
ş
Before disconnecting the connector, always turn the starting switch OFF.
ş
Before carrying out below procedure, check all the related connectors are properly inserted and
short of fuse No.3.
ş
After checking, insert the disconnected connectors again immediately unless otherwise specified.
YES
YES
NO
NO
YES
Check voltage
between CN-2(A)
and chassis
Check voltage
between CN-9(1)
and chassis
Check voltage
between CN-56(1)
and chassis
NO
CLUSTER
POWER IG(24V)
GND
RX
TX
2
CN-56
2
CN-9
B
CN-2
FUSE
NO.3
A
1
1
YES
NO
20 ~ 32V
0V
Check voltage
Starting switch : ON
Voltage : 20~32V
Cause
Remedy
Defective cluster
Disconnection in
wiring harness or
poor contact
between CN-9(1)-
CN-56(1)
Disconnection in
wiring harness or
poor contact
between CN-2(A)-
CN-9(1)
Disconnection in
wiring harness or
poor contact
between CN-2(A)-
and fuse No.3
Replace
Repair or replace
(After clean)
Repair or replace
(After clean)
Repair or replace
(After clean)
Содержание R 160 LC-3
Страница 9: ......
Страница 142: ...4 4...
Страница 152: ...4 14 BEACONLAMPCIRCUIT FUSE BOX BEACON LAMP SW BEACON LAMP 2 3 1 4 4 CN 2 CN 14 CL 7 CN 6 CN 1 CN 36 CS 23...
Страница 171: ...4 33 No of pin Receptacle connector Female Plug connector Male 20 1 11 10 20 S817 020105 MULTILOCK TYPE CONNECTOR 2...
Страница 182: ...4 44 No of pin Receptacle connector Female Plug connector Male 24 12 24 1 13 S815 024000...
Страница 394: ...8 81 8 Fit spool 34 spring 35 to base plate 3 and tighten plug 36 Pay attention to spool direction...
Страница 397: ......
Страница 398: ......
Страница 399: ......
Страница 400: ......
Страница 401: ......
Страница 402: ......
Страница 403: ......
Страница 404: ......
Страница 405: ......
Страница 406: ......
Страница 407: ......
Страница 416: ...8 103 Remove lock nut 21 and then boot 26 15...
Страница 427: ...8 114 Install cover 3 to hub 1 and tighten bolts 14 Torque 5 5 12 5kgf m 40 90lbf ft 7 14 15 3...
Страница 456: ...8 143 1 STRUCTURE GROUP 11 WORKEQUIPMENT SECTION A SECTION B SECTION C C B B A A C...