5 - 25
3. EPPR VALVE CHECK PROCEDURE
CHECK ELECTRIC VALUE AT EPPR VALVE
Start engine.
Set S-mode and cancel auto decel mode.
If tachometer show approx 2250
Ź
50rpm,
disconnect one wire harness from EPPR
valve.
Install multimeter as figure.
Check electric current at bucket circuit
relief position.
CHECK PRESSURE AT EPPR VALVE
Remove plug and connect pressure
gauge as figure.
Gauge capacity : 0 to 40-50kgf/cm
2
(0 to 570-710psi)
Start engine.
Set S-mode and cancel auto decel mode.
If tachometer show approx 2250
Ź
50rpm.
Check pressure at relief position of bucket
circuit by operating bucket control lever.
If pressure is not correct, adjust it.
After adjust, test the machine.
CN-75
Multimeter
EPPR VALVE
CN-75
Supply line, pilot press
Pressure adjusting
screw
locknut
(1)
(2)
(3)
(4)
(5)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
1)
2)
Spec : 200~400mA
Spec : 2~10kgf/cm
2
(30~140psi)
Содержание R 160 LC-3
Страница 9: ......
Страница 142: ...4 4...
Страница 152: ...4 14 BEACONLAMPCIRCUIT FUSE BOX BEACON LAMP SW BEACON LAMP 2 3 1 4 4 CN 2 CN 14 CL 7 CN 6 CN 1 CN 36 CS 23...
Страница 171: ...4 33 No of pin Receptacle connector Female Plug connector Male 20 1 11 10 20 S817 020105 MULTILOCK TYPE CONNECTOR 2...
Страница 182: ...4 44 No of pin Receptacle connector Female Plug connector Male 24 12 24 1 13 S815 024000...
Страница 394: ...8 81 8 Fit spool 34 spring 35 to base plate 3 and tighten plug 36 Pay attention to spool direction...
Страница 397: ......
Страница 398: ......
Страница 399: ......
Страница 400: ......
Страница 401: ......
Страница 402: ......
Страница 403: ......
Страница 404: ......
Страница 405: ......
Страница 406: ......
Страница 407: ......
Страница 416: ...8 103 Remove lock nut 21 and then boot 26 15...
Страница 427: ...8 114 Install cover 3 to hub 1 and tighten bolts 14 Torque 5 5 12 5kgf m 40 90lbf ft 7 14 15 3...
Страница 456: ...8 143 1 STRUCTURE GROUP 11 WORKEQUIPMENT SECTION A SECTION B SECTION C C B B A A C...