RF-MCGARDPRO
Hubbell Power Systems, Inc.
–
RFL™
Products
July 1, 2022
©2022 Hubbell Incorporated
1-14
Product Smart Number >>
GPRO
3U
Front Panel Touch Screen Display
None
0
Yes
TSD
Yes with Stylus Tether
TSDT
Front Panel Test Switch
None
0
Standard
TD
Primary Power Supply Voltage Input
24 VDC
24
48 VDC
48
125 VDC or 120 VAC
125
250 VDC
250
Redundant Power Supply Voltage Input
None
0
24 VDC
24
48 VDC
48
125 VDC or 120 VAC
125
250 VDC
250
Power Supply Interface
With Multiprotocol (RS-449, V.35, X.21) Digital I/O
MP
With Double Pole Switched Battery Output
DP
With Multiprotocol (RS-449, V.35, X.21) Digital I/O & Ext PLC Amp Sw Battery
SP
Front System Display Module
With Standard Digital Teleprotection Functionality
TP
Without Digital Teleprotection Functionality
No
Redundant Controller
No
0
System I/O Ethernet Port Type
Electrical
E
Fiber Optic
F
GPS for System Clock Synchronization
Yes
G
No
0
Front Functional Modules (Select Eight with 6U and Two with 3U)
Power Line Carrier FSK or On/Off (50 Ohms) w/CLI Meter
Power Line Carrier FSK or On/Off (75 Ohms) w/CLI Meter
TX Only Power Line Carrier FSK (50 Ohms)
TX Only Power Line Carrier FSK (75 Ohms)
RX Only Power Line Carrier FSK (50/75 Ohms) w/CLI Meter
Power Line Carrier FSK or On/Off - No Hybrid (50 Ohms) w/CLI Meter
Power Line Carrier for External Power Amp
Standard Digital Teleprotection
Empty
Rear I/O Terminal Block Type
Screw
S
Commpression
C
Rear I/O Modules (Select Ten with 6U and Four with 3U )
Occupied Slot Based On Front Module Selection
Empty
`
Digital Communications Modules and Discrete I/O
None
T1 (DB15/RJ48)
T0
E1 (DB15/RJ48)
N0
E1 (BNC 50 or 75 ohm)
E0
Multiprotocol (RS-449, V.35, X.21)
M0
Short Haul Fiber C37.94, 820nm LED Mulitmode (ST)
H0
Short Haul Fiber C37.94, 820nm LED Singlemode (ST)
B0
Long Haul Fiber, 1300nm LED Singlemode/Multimode (ST)
F0
Long Haul Fiber, 1300nm LASER Singlemode (ST)
30
Long Haul Fiber, 1550nm LASER Singlemode (ST)
50
Discrete I/O Units
6 Inputs
6 Solid State Outputs
6 Relay Outputs
12 Inputs
12 Solid State Outputs
12 Relay Outputs
6 Solid State Outputs and 6 Relay Outputs
6 Solid State Outputs and 6 Inputs
6 Relay Outputs and 6 Inputs
Current Limiting Output
None
0
48 Vdc
CL48
125 Vdc
CL125
System Firmware
Standard (Current Released Version) - Blank selection
Version 2.1.0
A
Version 2.2.0
B
Version 2.2.2
C
Version 2.6.6 (Minimum Required for Digital Teleprotection Funcionality)
D
Effective: 6/1/22
BI
BS
BR
RFL
®
GARD Pro
™
3U - Ordering Information
Consumes two rear slots in corresponding slot number
Consumes two rear slots in corresponding slot number
Consumes two rear slots in corresponding slot number
Consumes two rear slots in corresponding slot number
Consumes two rear slots in corresponding slot number
Consumes two rear slots in corresponding slot number
Rear Slots 1 through 4
/----------------------------Select 4 I/O----------------------------\
F
ro
n
t S
lo
t 4
R
e
a
r S
lo
t 1
R
e
a
r S
lo
t 2
R
e
a
r S
lo
t 3
R
e
a
r S
lo
t 4
Input
SS Out
Relay Out
Consumes two rear slots in corresponding slot number
/-Select 2 Functions-\
Front Slots 4 - 3
P5 & 0 (uses two slots)
P7 & 0 (uses two slots)
T5 & 0 (uses two slots)
T7 & 0 (uses two slots)
PR & 0 (uses two slots)
PN & 0 (uses two slots)
PX & 0 (uses two slots)
0
TP
F
ro
n
t S
lo
t 3
TR
EI
ES
ER
TI
TS
NI
NS
NR
MS
MR
MI
HI
HS
HR
5S
5R
With Discrete I/O >>
X
0
5I
FS
FR
3I
3S
3R
FI
RR
SR
SI
RI
IE
SE
RE
II
SS