GD32E23x User Manual
71
set this bit will trigger a wakeup event when the input is already high.
7:3
Reserved
Must be kept at reset value.
2
LVDF
Low Voltage Detector Status Flag
0: Low Voltage event has not occurred (V
DD
is higher than the specified LVD
threshold)
1: Low Voltage event occurred (V
DD
is equal to or lower than the specified LVD
threshold)
Note:
The LVD function is stopped in Standby mode.
1
STBF
Standby Flag
0: The device has not entered the Standby mode
1: The device has been in the Standby mode
This bit is cleared only by a POR / PDR or by setting the STBRST bit in the
PMU_CTL register.
0
WUF
Wakeup Flag
0: No wakeup event has been received
1: Wakeup event occurred from the WKUP pin or the RTC wakeup event including
RTC Tamper event, RTC alarm event
,
RTC Time Stamp event
This bit is cleared only by a POR / PDR or by setting the WURST bit in the
PMU_CTL register.