Handling and installation
Cable installation
2005-9015-009
01. August 2018
6.26.4 Step 4: Tensioning the cables
Attention!
Improper cable tension will cause malfunction of the control panel load
detection system.
● Check the cable tension on the
corner wheels located next to the
drive unit.
● Position a 36” (1m) straight edge (A)
on the floor next to the cable.
● Pull by hand
the cable to measure
the tension in the center of the
straight edge (A). The cable must
roughly deflect 1” (25 mm).
Warning!
Risk of injury!
Be careful when using the wrench, the cable is under tension.
● If the deflection is greater than 1” (25
mm), roll one catch on each scraper
tensioner using the wrench.
Proceed scraper by scraper. Make
sure the cable tensioner is correctly
locked.
● Repeat these steps until the
deflection is obtained on each
corner wheel located next to the
drive unit.
● Install the scrapers tensioner cover.