Programming
Minimum load (HP) fine tuning
2005-9015-009
01. August 2018
7.6
Minimum load (HP) fine tuning
The purpose of the ''MINIMUM LOAD (HP)'' is to indicate if a mechanical failure
has occurred.
Note!
When the ''MINIMUM LOAD'' is achieved during 15 seconds, the
control panel stops all operations and displays the A4 ''NO LOAD
DETECTED” alarm.
IVR PRO
● Start the control panel by pressing for 2 seconds the ”START/RESET” button on the control
panel door.
● Read the ”MINIMUM LOAD HP” by accessing the real time reading
parameter.
● Press key until (rtr) appears;
key
● Press key to select;
● Press keys until (F02) appears:
● Press key to select;
● Note the reading and add 0.1 HP to the reading;
● Press key until (ParA) appears;
● Press key to select;
● Press key until (P05) appears;
● Press key to select;
● Press keys to enter the minimum load (HP) to the value obtained. Hold the
button for fast change;
IVR PRO Max@ccess
● Start the scraper(s) using the ”INSTANT START” function. Monitor the ”TOTAL HP” reading
displayed on the screen. Note the reading.
● Add 0.1 HP to the reading.
● Press ”SYSTEM”;
● Press ”MOTOR SETTINGS”;
● Use the keypad arrows to select the parameter;
● Use the keypad to enter the minimum load (HP) to the value obtained.
Содержание Fit R-300
Страница 38: ...Geometric data 16 scraper 2005 9015 009 01 August 2018 38 168 5 8 16 scraper Floor mounted ...
Страница 40: ...Geometric data 16 scraper 2005 9015 009 01 August 2018 40 168 Guided by a groove ...
Страница 42: ...Geometric data V shape scraper 2005 9015 009 01 August 2018 42 168 5 9 V shape scraper Floor mounted ...
Страница 44: ...Geometric data V shape scraper 2005 9015 009 01 August 2018 44 168 Guided by a groove ...
Страница 46: ...Geometric data V shape scraper 2005 9015 009 01 August 2018 46 168 Bidirectional scraper ...
Страница 128: ...Programming Farm access 2005 9015 009 01 August 2018 128 168 7 21 3 Wiring 1 2 3 5 5 1 1 2 3 5 5 5 ...