Operating faults
FIO452 indicator lights
2005-9015-009
01. August 2018
10.4
FIO452 indicator lights
Direction: Status of the proximity switch inputs; in reverse/forward.
External emergency stop:
Status of the external emergency stop input. The indicator light must be
ON in normal operation.
If the indicator is OFF, the external emergency button is activated or
disconnected.
In absence of an external emergency button, a jumper should be wired
(see electric diagrams).
External start:
Status of the external start signal. The indicator light is ON when
receiving an external start signal.
Feedback:
Status of the feedback output. The output is activated when cleaning is
in progress.
Inputs:
Status of the inputs.
Outputs:
Status of the outputs.
Inputs:
Status of the input signals