Operating faults
Troubleshooting possible faults
2005-9015-009
01. August 2018
The control panel
displays alarm A16 -
A18
Voltage phase loss
motor 2 (PWR030-2)
Voltage phase lost
Wiring
Power dysfunction
Malfunction of the Sensor 2
(PWR0302)
Check the motor voltage;
Check motor connections;
Check wiring in the control panel;
Check power lines.
Contact your dealer if the problem
persists.
The control panel
displays alarm A19 -
A21
Current phase loss
motor 2 (PWR030-2)
Current phase lost
Wiring
Power dysfunction
Malfunction of the Sensor 2
(PWR0302)
Check the motor current;
Check motor connections;
Check wiring in the control panel;
Check power lines
Contact your dealer if the problem
persists.
The control panel
displays alarm E1
Connection loss with
the FIO
Faulty connection on the control
panel.
Power dysfunction
Malfunction of the control panel
module (FIO452).
Check the wiring.
Shut power off for 30 seconds to
reset the control panel;
Contact your dealer if the problem
persists.
The control panel
displays alarm E2
Connection loss with
the sensor
(PWR030-1)
Faulty connection on the control
panel.
Power dysfunction
Malfunction of the control panel
module (FIO452).
Malfunction of the PWR030
sensor.
Check the wiring;
Shut power off for 30 seconds to
reset the control panel;
Check the power lines.
Contact your dealer if the problem
persists.
Note!
For any other faults, please contact your dealer.
Содержание Fit R-300
Страница 38: ...Geometric data 16 scraper 2005 9015 009 01 August 2018 38 168 5 8 16 scraper Floor mounted ...
Страница 40: ...Geometric data 16 scraper 2005 9015 009 01 August 2018 40 168 Guided by a groove ...
Страница 42: ...Geometric data V shape scraper 2005 9015 009 01 August 2018 42 168 5 9 V shape scraper Floor mounted ...
Страница 44: ...Geometric data V shape scraper 2005 9015 009 01 August 2018 44 168 Guided by a groove ...
Страница 46: ...Geometric data V shape scraper 2005 9015 009 01 August 2018 46 168 Bidirectional scraper ...
Страница 128: ...Programming Farm access 2005 9015 009 01 August 2018 128 168 7 21 3 Wiring 1 2 3 5 5 1 1 2 3 5 5 5 ...