Programming
Detection parameters
2005-9015-009
01. August 2018
7.7.2
Detection time
The detection time parameter sets the time reaction of the detection. When a
detection is monitored, the control panel monitors the following readings to
determine if there is a detection or not. See examples below.
Example A
Detection settings:
● MAX FLUCTUATION: 0.08 HP
● DETECTION TIME: 5.0 sec.
If the fluctuation reading is 0.08
HP, the control panel stops
operation after 5 seconds.
Example B
Detection settings:
● MAX FLUCTUATION: 0.08 HP
● DETECTION TIME: 5.0 sec.
If the fluctuation reading is 0.16
HP (twice), the control panel stops
operation after 2.5 seconds (twice
faster).
Example C
Detection settings:
● MAX FLUCTUATION: 0.08 HP
● DETECTION TIME: 5.0 sec.
When a peak occurs, the control
panel starts monitoring. If next
readings are lower and the
detection range is not filled, the
control ignore detection and
continue operation.
Note!
The control panel does not perform detection at the beginning of each
stroke during the first 15 seconds since it collects load fluctuation
values only. It is strongly recommended to park the scraper(s) outside
the free stall area at a minimum distance of 56” (1.42 m).
Содержание Fit R-300
Страница 38: ...Geometric data 16 scraper 2005 9015 009 01 August 2018 38 168 5 8 16 scraper Floor mounted ...
Страница 40: ...Geometric data 16 scraper 2005 9015 009 01 August 2018 40 168 Guided by a groove ...
Страница 42: ...Geometric data V shape scraper 2005 9015 009 01 August 2018 42 168 5 9 V shape scraper Floor mounted ...
Страница 44: ...Geometric data V shape scraper 2005 9015 009 01 August 2018 44 168 Guided by a groove ...
Страница 46: ...Geometric data V shape scraper 2005 9015 009 01 August 2018 46 168 Bidirectional scraper ...
Страница 128: ...Programming Farm access 2005 9015 009 01 August 2018 128 168 7 21 3 Wiring 1 2 3 5 5 1 1 2 3 5 5 5 ...