Operating faults
Troubleshooting possible faults
2005-9015-009
01. August 2018
Fault
Possible cause
Solution
The control panel
displays alarm A6
End of stroke
detection
Load detection at the end of a
stroke
Check for manure accumulation in
non visible places;
Reset the alarm.
The control panel
displays alarm A7
Significant current
gap between motors.
Significant current gap between
the 2 motors.
Check for motor defects.
Check current of each motor;
Reset the alarm;
Contact your dealer if the problem
persists.
The control panel
displays alarm A8 -
A9
Defective sensor
PWR-030
Bad connection on the PWR030. Check wiring in the control panel;
Shut power off for 30 seconds to
reset the control panel.
Contact your dealer if the problem
persists.
The control panel
displays alarm A10 -
A12
Voltage phase loss
sensor 1 on line 1-2
or 3. (PWR030-1)
Voltage phase lost
Wiring
Power dysfunction
Malfunction of the Sensor 1
(PWR0301)
Check the motor voltage;
Check motor connections;
Check wiring in the control panel;
Check power lines.
Replace the PWR030
Contact your dealer if the problem
persists.
The control panel
displays alarm A13 -
A15
Current phase loss
sensor 1 on line 1-2
or 3. (PWR030-1)
Current phase lost
Wiring
Power dysfunction
Malfunction of the Sensor 1
(PWR0301)
Check the motor current;
Check motor connections;
Check wiring in the control panel;
Check power lines.
Contact your dealer if the problem
persists.
Содержание Fit R-300
Страница 38: ...Geometric data 16 scraper 2005 9015 009 01 August 2018 38 168 5 8 16 scraper Floor mounted ...
Страница 40: ...Geometric data 16 scraper 2005 9015 009 01 August 2018 40 168 Guided by a groove ...
Страница 42: ...Geometric data V shape scraper 2005 9015 009 01 August 2018 42 168 5 9 V shape scraper Floor mounted ...
Страница 44: ...Geometric data V shape scraper 2005 9015 009 01 August 2018 44 168 Guided by a groove ...
Страница 46: ...Geometric data V shape scraper 2005 9015 009 01 August 2018 46 168 Bidirectional scraper ...
Страница 128: ...Programming Farm access 2005 9015 009 01 August 2018 128 168 7 21 3 Wiring 1 2 3 5 5 1 1 2 3 5 5 5 ...