Programming
Motor initial settings
2005-9015-009
01. August 2018
7.4
Motor initial settings
7.4.1
Overload relay setting
Attention!
Risk of motor failure!
Improper overload relay setting can cause motor failure.
● Adjust the overload relay (1)
according to the amperage
indicated on the motor rating plate.
1
7.4.2
Volts
IVR PRO
● Press key until (ParA) appears;
key
● Press key to select;
● Press key until (P06) appears;
● Press key to select;
● Press keys to enter the voltage as per the value indicated on the motor rating
plate. Hold the button for fast change.
IVR PRO Max@ccess
● Press ”SYSTEM”;
● Press ”MOTOR SETTINGS”;
● Use the keypad arrows to select the parameter;
● Use the keypad to enter the voltage as per the value indicated on the motor rating
plate.