Handling and installation
Environment requirements
2005-9015-009
01. August 2018
6.3
Environment requirements
● This product must be installed in a frost-free environment;
● The concrete of each alley must be levelled, free from imperfections such
as holes, cracks, bumps, etc;
● All access to storage pit, cross gutter and transfer pump hopper must be
fenced to prevent falls.
● Each bridging (1) over alleys must be safe for livestock. A guard (2) must be
installed to keep the livestock away from the shearing zone. Refer to picture
below.
2
1
2
● The barn design must allow the scrapers to be parked out of the free stall
area at a minimum distance of 56” (1.42m). During the first 15 seconds of
each stroke, the control panel does not perform detection since it only
collects load fluctuation values.