Maintenance
General cleaning
2005-9015-009
01. August 2018
11.13
General cleaning
Every 6 months
Danger!
Risk of electric shock!
Never pressure wash electric equipment and components.
Warning!
Inadvertent start!
Shutdown is required! Shut the main power supply and lock with a
locking device. Post a sign on the panel stating: ”Do not turn on,
electric work in progress” in order to prevent an inadvertent energizing
of the main electric supply.
Caution!
Wear protective boots, eye gear and gloves.
Attention!
Use cold water to clean this product. Do not exceed 2000 psi (105 bar)
when using a pressure washer and keep the nozzle at a distance of
1ft (30 cm) from the surface to be cleaned.
● Clean manure buildup on the
scrapers, the corner wheels, the
alleys, etc.
● Remove manure build up in and out
of the drive unit.
● Apply grease on the drive unit bearings. Refer to section Maintenance -
Grease the drive unit bearings.
● Apply grease on the drive unit wheels and the corner wheels. Refer to
section Maintenance - Grease the drive unit wheels and the corner wheels.
● Reinstall all safety guards.
● Clean the control panel box with a dry cloth to remove all dust particles.
Содержание Fit R-300
Страница 38: ...Geometric data 16 scraper 2005 9015 009 01 August 2018 38 168 5 8 16 scraper Floor mounted ...
Страница 40: ...Geometric data 16 scraper 2005 9015 009 01 August 2018 40 168 Guided by a groove ...
Страница 42: ...Geometric data V shape scraper 2005 9015 009 01 August 2018 42 168 5 9 V shape scraper Floor mounted ...
Страница 44: ...Geometric data V shape scraper 2005 9015 009 01 August 2018 44 168 Guided by a groove ...
Страница 46: ...Geometric data V shape scraper 2005 9015 009 01 August 2018 46 168 Bidirectional scraper ...
Страница 128: ...Programming Farm access 2005 9015 009 01 August 2018 128 168 7 21 3 Wiring 1 2 3 5 5 1 1 2 3 5 5 5 ...