F176
ENUMERATION: SYNCHROCHECK DEAD SOURCE SELECT
F177
ENUMERATION: COMMUNICATION PORT
0 = None, 1 = COM1-RS485 (not applicable to UR firmware 7.00),
2 = COM2-RS485, 3 = Front Panel-RS232, 4 = Network - TCP,
5 = Network - UDP
F179
ENUMERATION: NEGATIVE SEQUENCE DIRECTIONAL
OVERCURRENT TYPE
0 = Neg Sequence, 1 = Zero Sequence
F183
ENUMERATION: AC INPUT WAVEFORMS
F184
ENUMERATION: IEC GOOSE DATASET
F186
ENUMERATION: MEASUREMENT MODE
0 = Phase to Ground, 1 = Phase to Phase
F190
ENUMERATION: SIMULATED KEYPRESS
F192
ENUMERATION: ETHERNET OPERATION MODE
0 = Half-Duplex, 1 = Full-Duplex
F193
ENUMERATION: ACCIDENTAL ENERG. ARMING MODE
0 = UV and Offline, 1 = UV or Offline
F194
ENUMERATION: DNP SCALE
0 = 0.01, 1 = 0.1, 2 = 1, 3 = 10, 4 = 100, 5 = 1000, 6 = 10000,
7 = 100000, 8 = 0.001
F196
ENUMERATION: NEUTRAL DIRECTIONAL OVERCURRENT
OPERATING CURRENT
0 = Calculated 3I0, 1 = Measured IG
Bitmask
Synchrocheck dead source
0
None
1
LV1 and DV2
2
DV1 and LV2
3
DV1 or DV2
4
DV1 Xor DV2
5
DV1 and DV2
Bitmask
Definition
0
Off
1
8 samples/cycle
2
16 samples/cycle
3
32 samples/cycle
4
64 samples/cycle
Value
IEC 61850 dataset
0
Off
1
GooseIn 1
2
GooseIn 2
3
GooseIn 3
4
GooseIn 4
5
GooseIn 5
6
GooseIn 6
7
GooseIn 7
8
GooseIn 8
9
GooseIn 9
10
GooseIn 10
11
GooseIn 11
12
GooseIn 12
13
GooseIn 13
14
GooseIn 14
15
GooseIn 15
16
GooseIn 16
Bitmask Keypress
Bitmask Keypress
0
No key ---
use between real keys
23
Reset
24
User 1
1
1
25
User 2
2
2
26
User 3
3
3
27
User-programmable key 1
4
4
28
User-programmable key 2
5
5
29
User-programmable key 3
6
6
30
User-programmable key 4
7
7
31
User-programmable key 5
8
8
32
User-programmable key 6
9
9
33
User-programmable key 7
10
0
34
User-programmable key 8
11
Decimal Point
35
User-programmable key 9
12
Plus/Minus
36
User-programmable key 10
13
Value Up
37
User-programmable key 11
14
Value Down
38
User-programmable key 12
15
Message Up
39
User 4 (control pushbutton)
16
Message Down
40
User 5 (control pushbutton)
17
Message Left
41
User 6 (control pushbutton)
18
Message Right
42
User 7 (control pushbutton)
19
Menu
43
User-programmable key 13
20
Help
44
User-programmable key 14
21
Escape
45
User-programmable key 15
22
Enter
46
User-programmable key 16
Содержание Multilin g60
Страница 10: ...x G60 Generator Protection System GE Multilin TABLE OF CONTENTS INDEX ...
Страница 32: ...1 22 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 130: ...3 68 G60 Generator Protection System GE Multilin 3 4 FIELD AND STATOR GROUND MODULES 3 HARDWARE 3 ...
Страница 160: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 486: ...5 326 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 518: ...6 32 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 532: ...7 14 G60 Generator Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Страница 538: ...8 6 G60 Generator Protection System GE Multilin 8 1 PHASE DISTANCE THROUGH POWER TRANSFORMERS 8 THEORY OF OPERATION 8 ...
Страница 748: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Страница 760: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...