A-12
G60 Generator Protection System
GE Multilin
A.1 PARAMETER LISTS
APPENDIX A
A
8275
SRC 3 Vc Harm[10]
%
Source 3 phase C voltage twelfth harmonic
8276
SRC 3 Vc Harm[11]
%
Source 3 phase C voltage thirteenth harmonic
8277
SRC 3 Vc Harm[12]
%
Source 3 phase C voltage fourteenth harmonic
8278
SRC 3 Vc Harm[13]
%
Source 3 phase C voltage fifteenth harmonic
8279
SRC 3 Vc Harm[14]
%
Source 3 phase C voltage sixteenth harmonic
8280
SRC 3 Vc Harm[15]
%
Source 3 phase C voltage seventeenth harmonic
8281
SRC 3 Vc Harm[16]
%
Source 3 phase C voltage eighteenth harmonic
8282
SRC 3 Vc Harm[17]
%
Source 3 phase C voltage nineteenth harmonic
8283
SRC 3 Vc Harm[18]
%
Source 3 phase C voltage twentieth harmonic
8284
SRC 3 Vc Harm[19]
%
Source 3 phase C voltage twenty-first harmonic
8285
SRC 3 Vc Harm[20]
%
Source 3 phase C voltage twenty-second harmonic
8286
SRC 3 Vc Harm[21]
%
Source 3 phase C voltage twenty-third harmonic
8287
SRC 3 Vc Harm[22]
%
Source 3 phase C voltage twenty-fourth harmonic
8288
SRC 3 Vc Harm[23]
%
Source 3 phase C voltage twenty-fifth harmonic
8289
SRC 4 Va THD
%
Source 4 phase A voltage total harmonic distortion (THD)
8290
SRC 4 Va Harm[0]
%
Source 4 phase A voltage second harmonic
8291
SRC 4 Va Harm[1]
%
Source 4 phase A voltage third harmonic
8292
SRC 4 Va Harm[2]
%
Source 4 phase A voltage fourth harmonic
8293
SRC 4 Va Harm[3]
%
Source 4 phase A voltage fifth harmonic
8294
SRC 4 Va Harm[4]
%
Source 4 phase A voltage sixth harmonic
8295
SRC 4 Va Harm[5]
%
Source 4 phase A voltage seventh harmonic
8296
SRC 4 Va Harm[6]
%
Source 4 phase A voltage eighth harmonic
8297
SRC 4 Va Harm[7]
%
Source 4 phase A voltage ninth harmonic
8298
SRC 4 Va Harm[8]
%
Source 4 phase A voltage tenth harmonic
8299
SRC 4 Va Harm[9]
%
Source 4 phase A voltage eleventh harmonic
8300
SRC 4 Va Harm[10]
%
Source 4 phase A voltage twelfth harmonic
8301
SRC 4 Va Harm[11]
%
Source 4 phase A voltage thirteenth harmonic
8302
SRC 4 Va Harm[12]
%
Source 4 phase A voltage fourteenth harmonic
8303
SRC 4 Va Harm[13]
%
Source 4 phase A voltage fifteenth harmonic
8304
SRC 4 Va Harm[14]
%
Source 4 phase A voltage sixteenth harmonic
8305
SRC 4 Va Harm[15]
%
Source 4 phase A voltage seventeenth harmonic
8306
SRC 4 Va Harm[16]
%
Source 4 phase A voltage eighteenth harmonic
8307
SRC 4 Va Harm[17]
%
Source 4 phase A voltage nineteenth harmonic
8308
SRC 4 Va Harm[18]
%
Source 4 phase A voltage twentieth harmonic
8309
SRC 4 Va Harm[19]
%
Source 4 phase A voltage twenty-first harmonic
8310
SRC 4 Va Harm[20]
%
Source 4 phase A voltage twenty-second harmonic
8311
SRC 4 Va Harm[21]
%
Source 4 phase A voltage twenty-third harmonic
8312
SRC 4 Va Harm[22]
%
Source 4 phase A voltage twenty-fourth harmonic
8313
SRC 4 Va Harm[23]
%
Source 4 phase A voltage twenty-fifth harmonic
8314
SRC 4 Vb THD
%
Source 4 phase B voltage total harmonic distortion (THD)
8315
SRC 4 Vb Harm[0]
%
Source 4 phase B voltage second harmonic
8316
SRC 4 Vb Harm[1]
%
Source 4 phase B voltage third harmonic
8317
SRC 4 Vb Harm[2]
%
Source 4 phase B voltage fourth harmonic
8318
SRC 4 Vb Harm[3]
%
Source 4 phase B voltage fifth harmonic
8319
SRC 4 Vb Harm[4]
%
Source 4 phase B voltage sixth harmonic
8320
SRC 4 Vb Harm[5]
%
Source 4 phase B voltage seventh harmonic
8321
SRC 4 Vb Harm[6]
%
Source 4 phase B voltage eighth harmonic
Table A–1: FLEXANALOG DATA ITEMS (Sheet 12 of 27)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
Содержание Multilin g60
Страница 10: ...x G60 Generator Protection System GE Multilin TABLE OF CONTENTS INDEX ...
Страница 32: ...1 22 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 130: ...3 68 G60 Generator Protection System GE Multilin 3 4 FIELD AND STATOR GROUND MODULES 3 HARDWARE 3 ...
Страница 160: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 486: ...5 326 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 518: ...6 32 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 532: ...7 14 G60 Generator Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Страница 538: ...8 6 G60 Generator Protection System GE Multilin 8 1 PHASE DISTANCE THROUGH POWER TRANSFORMERS 8 THEORY OF OPERATION 8 ...
Страница 748: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Страница 760: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...