C-28
G60 Generator Protection System
GE Multilin
C.7 LOGICAL NODES
APPENDIX C
C
ITPC: Teleprotection communication interfaces
---
K: LOGICAL NODES FOR MECHANICAL AND NON-ELECTRIC PRIMARY EQUIPMENT
KFAN: Fan
---
KFIL: Filter
---
KPMP: Pump
---
KTNK: Tank
---
KVLV: Valve control
---
M: LOGICAL NODES FOR METERING AND MEASUREMENT
MENV: Environmental information
---
MFLK: Flicker measurement name
---
MHAI: Harmonics or interharmonics
---
MHAN: Non phase related harmonics or interharmonics
---
MHYD: Hydrological information
---
MMDC: DC measurement
---
MMET: Meteorological information
---
MMTN: Metering
---
MMTR: Metering
---
MMXN: Non-phase-related measurement
Yes
MMXU: Measurement
Yes
MSQI: Sequence and imbalance
Yes
MSTA: Metering statistics
---
P: LOGICAL NODES FOR PROTECTION FUNCTIONS
PDIF: Differential
Yes
PDIR: Direction comparison
---
PDIS: Distance
Yes
PDOP: Directional overpower
---
PDUP: Directional underpower
---
PFRC: Rate of change of frequency
---
PHAR: Harmonic restraint
---
PHIZ: Ground detector
---
PIOC: Instantaneous overcurrent
Yes
PMRI Motor restart inhibition
---
PMSS: Motor starting time supervision
---
POPF: Over power factor
---
PPAM: Phase angle measuring
---
PRTR: Rotor protection
---
PSCH: Protection scheme
---
PSDE: Sensitive directional earth fault
---
PTEF: Transient earth fault
---
PTOC: Time overcurrent
Yes
PTOF: Overfrequency
---
PTOV: Overvoltage
Yes
PTRC: Protection trip conditioning
Yes
PTTR: Thermal overload
---
PTUC: Undercurrent
---
PTUF: Underfrequency
---
PTUV: Undervoltage
Yes
Table C–1: IEC 61850 LOGICAL NODES (Sheet 2 of 4)
NODES
UR-FAMILY
Содержание Multilin g60
Страница 10: ...x G60 Generator Protection System GE Multilin TABLE OF CONTENTS INDEX ...
Страница 32: ...1 22 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 130: ...3 68 G60 Generator Protection System GE Multilin 3 4 FIELD AND STATOR GROUND MODULES 3 HARDWARE 3 ...
Страница 160: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 486: ...5 326 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 518: ...6 32 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 532: ...7 14 G60 Generator Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Страница 538: ...8 6 G60 Generator Protection System GE Multilin 8 1 PHASE DISTANCE THROUGH POWER TRANSFORMERS 8 THEORY OF OPERATION 8 ...
Страница 748: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Страница 760: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...