B-46
G60 Generator Protection System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
7A87
Underfrequency 1 Source
0 to 5
---
1
F167
0 (SRC 1)
7A88
Underfrequency 1 Events
0 to 1
---
1
F102
0 (Disabled)
7A89
Underfrequency 1 Target
0 to 2
---
1
F109
0 (Self-reset)
7A8A
Underfrequency 1 Reserved (5 items)
0 to 1
---
1
F001
0
7A8F
...Repeated for Underfrequency 2
7A9E
...Repeated for Underfrequency 3
7AAD
...Repeated for Underfrequency 4
7ABC
...Repeated for Underfrequency 5
7ACB
...Repeated for Underfrequency 6
User Programmable Pushbuttons (Read/Write Setting) (16 modules)
7B60
User Programmable Pushbutton 1 Function
0 to 2
---
1
F137
0 (Disabled)
7B61
User Programmable Pushbutton 1 Top Line
---
---
---
F202
(none)
7B6B
User Programmable Pushbutton 1 On Text
---
---
---
F202
(none)
7B75
User Programmable Pushbutton 1 Off Text
---
---
---
F202
(none)
7B7F
User Programmable Pushbutton 1 Drop-Out Time
0 to 60
s
0.05
F001
0
7B80
User Programmable Pushbutton 1 Target
0 to 2
---
1
F109
0 (Self-reset)
7B81
User Programmable Pushbutton 1 Events
0 to 1
---
1
F102
0 (Disabled)
7B82
User Programmable Pushbutton 1 LED Operand
0 to 4294967295
---
1
F300
0
7B84
User Programmable Pushbutton 1 Autoreset Delay
0.2 to 600
s
0.1
F001
10
7B85
User Programmable Pushbutton 1 Autoreset Function
0 to 1
---
1
F102
0 (Disabled)
7B86
User Programmable Pushbutton 1 Local Lock Operand
0 to 4294967295
---
1
F300
0
7B88
User Programmable Pushbutton 1 Message Priority
0 to 2
---
1
F220
0 (Disabled)
7B89
User Programmable Pushbutton 1 Remote Lock Operand
0 to 4294967295
---
1
F300
0
7B8B
User Programmable Pushbutton 1 Reset Operand
0 to 4294967295
---
1
F300
0
7B8D
User Programmable Pushbutton 1 Set Operand
0 to 4294967295
---
1
F300
0
7B8F
User Programmable Pushbutton 1 Hold
0 to 10
s
0.1
F001
1
7B90
...Repeated for User Programmable Pushbutton 2
7BC0
...Repeated for User Programmable Pushbutton 3
7BF0
...Repeated for User Programmable Pushbutton 4
7C20
...Repeated for User Programmable Pushbutton 5
7C50
...Repeated for User Programmable Pushbutton 6
7C80
...Repeated for User Programmable Pushbutton 7
7CB0
...Repeated for User Programmable Pushbutton 8
7CE0
...Repeated for User Programmable Pushbutton 9
7D10
...Repeated for User Programmable Pushbutton 10
7D40
...Repeated for User Programmable Pushbutton 11
7D70
...Repeated for User Programmable Pushbutton 12
7DA0
...Repeated for User Programmable Pushbutton 13
7DD0
...Repeated for User Programmable Pushbutton 14
7E00
...Repeated for User Programmable Pushbutton 15
7E30
...Repeated for User Programmable Pushbutton 16
Neutral Overvoltage (Read/Write Grouped Setting) (3 modules)
7F00
Neutral Overvoltage 1 Function
0 to 1
---
1
F102
0 (Disabled)
7F01
Neutral Overvoltage 1 Signal Source
0 to 5
---
1
F167
0 (SRC 1)
7F02
Neutral Overvoltage 1 Pickup
0 to 3
pu
0.001
F001
300
7F03
Neutral Overvoltage 1 Pickup Delay
0 to 600
s
0.01
F001
100
7F04
Neutral Overvoltage 1 Reset Delay
0 to 600
s
0.01
F001
100
7F05
Neutral Overvoltage 1 Block
0 to 4294967295
---
1
F300
0
7F07
Neutral Overvoltage 1 Target
0 to 2
---
1
F109
0 (Self-reset)
7F08
Neutral Overvoltage 1 Events
0 to 1
---
1
F102
0 (Disabled)
7F09
Neutral Overvoltage 1 Curves
0 to 3
---
1
F116
0 (Definite Time)
7F0A
Reserved (8 items)
0 to 65535
---
1
F001
0
7F11
...Repeated for Neutral Overvoltage 2
7F22
...Repeated for Neutral Overvoltage 3
Table B–10: MODBUS MEMORY MAP (Sheet 38 of 68)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание Multilin g60
Страница 10: ...x G60 Generator Protection System GE Multilin TABLE OF CONTENTS INDEX ...
Страница 32: ...1 22 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 130: ...3 68 G60 Generator Protection System GE Multilin 3 4 FIELD AND STATOR GROUND MODULES 3 HARDWARE 3 ...
Страница 160: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 486: ...5 326 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 518: ...6 32 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 532: ...7 14 G60 Generator Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Страница 538: ...8 6 G60 Generator Protection System GE Multilin 8 1 PHASE DISTANCE THROUGH POWER TRANSFORMERS 8 THEORY OF OPERATION 8 ...
Страница 748: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Страница 760: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...