F-2
L30 Line Current Differential System
GE Multilin
F.1 CHANGE NOTES
APPENDIX F
F
5-37
5-
Delete
Deleted Local Time Offset, Daylight Savings Time, DST (start/stop for month/day/hour) from Real
Time Clock menu
5-
5-37
Add
Added submenus Precision Time Protocol, SNTP Protocol, and Local Time and Synchronizing
Source settings to Real Time Clock menu
5-
5-39
Add
Added new Precision Time Protocol (1588) menu and setting descriptions
5-
5-
Update
Changed Communication to Real Time Clock in SNTP protocol settings path. Moved SNTP
Protocol menu and settings descriptions to Real Time Clock subsection
5-36
5-
Delete
Deleted section k) SNTP Protocol and the settings descriptions
5-
5-42
Add
Added new section for Local Time menu settings and settings description
5-
5-51
Add
Added new PTP Fail menu item to the User-Programmable Self Tests menu
5-
5-
Add
Added PTP Failure and CLOCK UNSYNCHRONIZED to Flexlogic Operands table
5-73
5-73
Update
Updated Figure 5-15 Channel Asymmetry Compensation Logic and added definition for Local
GPS Trouble in preceding text
5-89
5-89
Update
Updated PMU main menu to add aggregator and control block menu items
5-
5-89
Add
Added UR Synchrophasor Implementation of IEC61850-90-5 to the PMU software option
description
5-89
5-89
Update
Updated Figure: Complete Synchrophasor Implementation
5-
5-90
Add
Added Figure: N60 Support For Four Logical Device PMU
5-90
5-90
Update
Updated Table: Implementation By Model Number
5-
5-91
Add
Added Figure: Logical Nodes Supported In Each Logical Device
5-
5-92
Add
Added Figure: Data Set Created From User Selected Internal Items
5-
5-93
Add
Added Figure: Example Of Aggregator Data Sets
5-
5-93
Add
Added Figure: CFG-2 Based Configuration Solution
5-
5-93
Add
Added examples for a syncrophasor dataset and the creation of different datasets
5-
5-93
Add
Added example for a CFG-2 based configuration
5-95
5-95
Update
Updated PMU 1 basic configuration menu to add 37.118 and 90-5 configuration settings
submenus
5-
5-96
Add
Added PMU 1 configuration menus for 37.118 and 90-5 with settings descriptions
5-96
5-96
Update
Changed PMU 1 Function setting description
5-
5-106
Add
Added PMU AGGR 1 configuration menu and setting descriptions
5-
5-106
Add
Added new aggregators section with PMU 1 aggregators menu and setting descriptions
5-106
5-106
Update
Updated PMU 1 aggregators menu to include 37.118 and 90-5 aggregator configuration
submenus
5-
5-107
Add
Added 90-5 AGGR 1 configuration menu and setting descriptions
5-
5-108
Add
Added Table 5- # Of ASDUs
5-
5-108
Add
Added new control block section with IEC 90-5 MSVCB configuration menu and setting
descriptions
5-
5-129
Update
Added row for DeltaTime to Table 5-: FlexElement Base Units
5-220
5-220
Delete
Deleted section 5.8.5d Remote Devices: ID of Device for Receiving GSSE/GOOSE Messages,
meaning the Settings > Input/Outputs > Remote Devices settings
5-
5-237
Add
Added new CyberSentry security section and main menu, local passwords, session settings,
restore defaults, and supervisory subsections to Chapter 5
6-1
6-1
Update
Update Actual Values main menu to include Real Time Clock Synchronization submenu
6-
6-7
Add
Added new section for Real Time Clock synchronizing consisting of the menu of settings and the
setting descriptions
6-10
6-10
Delete
Deleted section 6.2.17 Ethernet Switch
6-
6-10
Add
Added new section 6.2.18 Remaining Connection Status
7-
7-1
Add
Added Security command to the Commands main menu
7-
7-3
Add
Added Reboot Relay command and description to the Relay Maintenance menu items
7-
7-
Add
Added Security menu and submenu commands and descriptions to the Command menu
Table F–3: MAJOR UPDATES FOR L30 MANUAL REVISION Y1 (Sheet 2 of 3)
PAGE
(X2)
PAGE
(Y1)
CHANGE
DESCRIPTION
Содержание L30
Страница 10: ...x L30 Line Current Differential System GE Multilin TABLE OF CONTENTS ...
Страница 30: ...1 20 L30 Line Current Differential System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 58: ...2 28 L30 Line Current Differential System GE Multilin 2 4 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Страница 126: ...4 30 L30 Line Current Differential System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 370: ...5 244 L30 Line Current Differential System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 396: ...6 26 L30 Line Current Differential System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 450: ...10 10 L30 Line Current Differential System GE Multilin 10 4 INSTANTANEOUS ELEMENTS 10 APPLICATION OF SETTINGS 10 ...
Страница 464: ...A 10 L30 Line Current Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 600: ...C 30 L30 Line Current Differential System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Страница 610: ...D 10 L30 Line Current Differential System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Страница 622: ...E 12 L30 Line Current Differential System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Страница 634: ...F 12 L30 Line Current Differential System GE Multilin F 3 WARRANTY APPENDIX F F ...