GE Multilin
L30 Line Current Differential System
6-11
6 ACTUAL VALUES
6.3 METERING
6
6.3METERING
6.3.1 METERING CONVENTIONS
a) UR CONVENTION FOR MEASURING POWER AND ENERGY
The following figure illustrates the conventions established for use in UR-series relays.
Figure 6–1: FLOW DIRECTION OF SIGNED VALUES FOR WATTS AND VARS
827239AC.CDR
PER IEEE CONVENTIONS
PARAMETERS AS SEEN
BY THE UR RELAY
Voltage
WATTS = Positive
VARS = Positive
PF = Lag
Current
Voltage
WATTS = Positive
VARS = Negative
PF = Lead
Current
Voltage
WATTS = Negative
VARS = Negative
PF = Lag
Current
Voltage
WATTS = Negative
VARS = Positive
PF = Lead
Current
Generator
Generator
Inductive
Inductive
Resistive
Resistive
Generator
Generator
UR RELAY
UR RELAY
UR RELAY
UR RELAY
G
G
M
M
G
G
VCG
IC
VAG
IA
VBG
IB
1
-
VCG
IC
VAG
IA
VBG
IB
2
-
VCG
IC
VAG
IA
VBG
IB
3
-
VCG
IC
VAG
IA
VBG
IB
4
-
+Q
+Q
+Q
+Q
P
F =
Lead
P
F =
Lead
P
F =
Lead
P
F =
Lead
P
F =
Lag
P
F =
Lag
P
F =
Lag
P
F =
Lag
P
F =
Lag
P
F =
Lag
P
F =
Lag
P
F =
Lag
P
F =
Lead
P
F =
Lead
P
F =
Lead
P
F =
Lead
-Q
-Q
-Q
-Q
-P
-P
-P
-P
+P
+P
+P
+P
IA
IA
IA
IA
S=VI
S=VI
S=VI
S=VI
LOAD
LOAD
Resistive
Resistive
LOAD
LOAD
Содержание L30
Страница 10: ...x L30 Line Current Differential System GE Multilin TABLE OF CONTENTS ...
Страница 30: ...1 20 L30 Line Current Differential System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 58: ...2 28 L30 Line Current Differential System GE Multilin 2 4 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Страница 126: ...4 30 L30 Line Current Differential System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 370: ...5 244 L30 Line Current Differential System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 396: ...6 26 L30 Line Current Differential System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 450: ...10 10 L30 Line Current Differential System GE Multilin 10 4 INSTANTANEOUS ELEMENTS 10 APPLICATION OF SETTINGS 10 ...
Страница 464: ...A 10 L30 Line Current Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 600: ...C 30 L30 Line Current Differential System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Страница 610: ...D 10 L30 Line Current Differential System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Страница 622: ...E 12 L30 Line Current Differential System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Страница 634: ...F 12 L30 Line Current Differential System GE Multilin F 3 WARRANTY APPENDIX F F ...
Страница 644: ...x L30 Line Current Differential System GE Multilin INDEX ...